background image

AY-x5B Series 

 

MIFARE Classic® EV1 CSN Readers 

Installation Manual

 

1.

 

Introduction 

The AY-x5B is a series of RFID proximity card readers to be installed for 

use with access control systems. 
The AY-x5B series reads the card serial number (CSN) from MIFARE 

Classic® EV1 credentials (4 UID and 7 UID) and transmits its data to 
the access control system using Wiegand 26-Bit output. 
Other Wiegand formats and the Clock & Data format are available as 

factory configurable options. 

Figure 1: AY-x5B Series 

 

 

 

 

AY-M5B 

AY-H5B 

AY-L5B 

AY-K5B 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

Specifications  AY-M5B  AY-H5B 

AY-L5B 

AY-K5B 

Power Supply Type 

Linear (recommended) 

Operating Voltage 
Range 

5–16 VDC 

Absolute Maximum 
(non-operating) 

18 VDC 

Current @ 12V 

Standby: 45 mA 

Maximum: 100 mA 

Max. Read Range* 

6.5 cm 

(2.6 in.) 

7.0 cm 

(2.8 in.) 

6.0 cm 

(2.4 in.) 

LED Control Input 

Dry Contact, N.O. 

Maximum Cable 
Distance to 
Controller 

18-AWG: 150 m (500 ft) 

20-AWG: 90 m (300 ft) 

Frequency 

13.56 MHz 

Bit Rate 

106 KHz 

* Measured using a Rosslare MIFARE Classic EV1 card or equivalent. Range also 

depends on installation environment, reader voltage, and proximity to metal.

 

2.2

 

Environmental Characteristics 

Specifications  AY-M5B 

AY-H5B 

AY-L5B 

AY-K5B 

Operating Temp. 
Range 

-31°C to 63°C (-25°F to 145°F) 

Operating 
Humidity Range 

0 to 95% (non-condensing) 

2.3

 

Physical Characteristics 

Model  

Dimensions  

(H x W x D) 

Weight  

AY-M5B 

89 x 89 x 15 mm 

(3.5 x 3.5 x 0.6 in.) 

120.3 g 

(4.2 oz.) 

AY-H5B 

110 x 75 x 15 mm 

(4.3 x 3.0 x 0.6 in.) 

119.9 g 

(4.2 oz) 

AY-L5B 

145 x 43 x 20 mm 

(5.7 x 1.7 x 0.8 in.) 

115.2 g 

(4.1 oz) 

AY-K5B 

80 x 40 x 12.8 mm 
(3.2 x 1.6 x 0.5 in.) 

75.5 g 

(2.7 oz) 

3.

 

Installation 

 

Installation of an RFID reader adjacent to metallic surfaces 

might alter the reader’s specifications. To diminish this 
interference, use a plastic spacer when mounting the reader. 

3.1

 

Installation Kit 

The installation kit consists of the following items to be used during 
the installation procedure: 

 

Two pan head mounting screws and screw anchors 

3.2

 

Mounting 

Before mounting, you should determine the best location for the 

reader. 
To mount the reader: 
1.

 

Drill two holes for mounting the reader on the wall. 

2.

 

Insert a screw anchor into each hole. 

3.

 

Drill a 10-mm (7/16”) hole for the cable. If mounting on metal, 
place a grommet or electrical tape around the edge of the hole. 

4.

 

Remove the screw from the bottom of the unit. 

5.

 

Remove the reader's snap-off front cover. 

6.

 

Insert the unit’s cable wire into the cable hole and wire the unit as 
described in Sectio

 

3.3. A linear type power supply is 

recommended. 

7.

 

Align the two holes of the reader with those drilled in the wall and 

firmly attach the reader to the wall with two screws (Figure 2). 

Figure 2: Inserting Mounting Screws (similar for all models) 

 

8.

 

Relocate the front cover onto the reader. 

9.

 

Secure the front cover with the screw at the bottom of the unit. 

 