Mangar airflo User Instructions And Warranty Download Page 4

airflo (battery version)

4

ME0082 issue 1

Battery Charging - fig.  

3

Connect the battery charger output lead (

A

) to 

the  Airflo  charging  socket  (

B

)  and  the  mains 

lead  (

C

)  to  a  mains  power  socket,  the  mains 

light (

D

) will glow.

The  charging  light  (

E

)  will  glow  while  the 

batteries  are  charging  and  go  out  when  they 

are  sufficiently  charged.  The  light  may  flash 

when the batteries approach fully charged.

If convenient, the Airflo may remain continuously on 

charge when not in use as the batteries cannot be 

overcharged using this charger.

WARNING:

  DO  NOT  recharge  the  batteries  in  a 

bathroom or in a damp environment.

Connecting the Air Hose - fig.  

4

Disconnect the Airflo from the battery charger and 

place the Airflo in a safe and convenient position. 
Connect the air hose from the Mangar International 

equipment to the air outlet socket (

A

). The connector 

will ‘click’ into place when firmly pushed onto the 

outlet.  To release the hose, press the paddle down 

on the connector.

3

D

E

A

C

B

4

A

Summary of Contents for airflo

Page 1: ...user instructions and warranty airflo battery version freedom through lightweight solutions...

Page 2: ...in the presence of flammable anaesthetic mixtures with air oxygen or nitrous oxide PLEASE BE SURE THAT YOU HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS AND THOSE PROVIDED WITH ANY OTHER MANGAR INTERNA...

Page 3: ...re that the battery charger is not connected to the Airflo and then press the battery indicator button A to activate the indicator lights B If the batteries are fully charged all four indicator lights...

Page 4: ...ed If convenient the Airflo may remain continuously on charge when not in use as the batteries cannot be overcharged using this charger WARNING DO NOT recharge the batteries in a bathroom or in a damp...

Page 5: ...AMEL Press the switch to change between Normal and High air flow Normal High WARNING DO NOT operate the Normal High air flow switch while the compressor is running Different ways to operate the Airflo...

Page 6: ...t a battery voltage check each time air is required and if the voltage becomes too low the Auto function will be cancelled automatically Locking the built in buttons fig 7 If desired the built in butt...

Page 7: ...Auto Control Button Move the lever C to up to raise Move the lever to down to lower Move the lever to neutral stop to stop at any height CAMEL and ELK Hand Controls fig 10 Connect the four hoses A fr...

Page 8: ...a new filter a kit of replacement filters is available through your supplier part number CA0233 Battery replacement Turn the Airflo upside down and remove the four screws B followed by the two battery...

Page 9: ...ir flow switch is in the Normal position Auto light flashing This happens when the compressor s internal temperature cut out has tripped Leave the Airflo for 15 minutes to cool The top two lights on t...

Page 10: ...nt AC Fuse with rating Max Min operating environment temperature Auto select button Up button Down button Do Not connect to mains power in a bathroom or outdoors Class II Double Insulated equipment Da...

Page 11: ...or repair by unqualified persons The following statements do not affect the consumer s statutory rights This product is sold on the understanding that in the event of any defect of manufacture or mat...