V.
121806
Cayenne
™
Series
4.2
Level Flash Cure
Step 1
The flash cure must be parallel to the pallet surface.
Dimensions (1) between the surface of the heating
elements and the pallet surface should be 2-1/4” at all four
corners.
Level the flash cure using the two rear leveling legs and the
front to rear pivoting adjustment. When the flash cure is
parallel to the pallet, adjust height or distance from the
pallet using the hand wheel (2). Tighten the side handles to
lock in position.
Place a level on the unit’s surface to check for level front to
back and side to side.
Step 3
To adjust the front to rear angle of the heating element,
loosen bolts (1) located on both sides of the chassis.
Step 4
Adjust the front to rear angle by turning the bolt (1) located
at the bottom center of the chassis. Make additional leveling
adjustments using the two rear leveling pads. When leveling
adjustments are completed, re-tighten the bolts loosened in
previous step.
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA 13
Tel: +630-858-6101 Fax: +630-858-6134
www.mrprint.com