background image

13

1

22.5

0.0937

BEN

1

27.5

0.1363

BEN

2

26.1

0.1115

BEN

2

32.0

0.1622

BEN

2

27.7

0.1445

BEN

2

33.9

0.2102

BEN

2

29.2

0.1775

BEN

2

35.7

0.2582

BEN

2

30.7

0.2105

BEN

2

37.6

0.3062

BEN

3

34.2

0.2284

BEN

3

42.0

0.3322

BEN

3

35.7

0.2614

BEN

3

43.9

0.3802

BEN

3

38.8

0.3274

BEN

3

50.3

0.4762

BEE

4

46.4

0.3782

BEE

4

56.5

0.5501

BE

4

49.5

0.4442

BEE

4

60.3

0.6461

BE

5

54.5

0.4950

BEE

5

66.5

0.7200

BE

5

57.5

0.5610

BE

5

70.2

0.8160

BE

6

62.5

0.6118

BE

6

76.5

0.8899

BE

6

65.6

0.6778

BE

6

80.2

0.9859

BE

1

24.2

0.1079

BEN

1

29.1

0.1505

BEN

2

28.1

0.1284

BEN

2

34.0

0.1791

BEN

2

29.7

0.1664

BEN

2

35.9

0.2321

BEN

2

31.4

0.2044

BEN

2

37.9

0.2851

BEN

2

33.0

0.2424

BEN

2

39.9

0.3381

BEN

3

36.8

0.2630

BEN

3

47.2

0.3668

BEE

3

38.4

0.3010

BEN

3

49.2

0.4198

BEE

3

41.7

0.3770

BEN

3

53.2

0.5258

BEE

4

49.8

0.4355

BEE

4

59.9

0.6074

BE

4

53.1

0.5115

BEE

4

63.8

0.7134

BE

5

58.5

0.5700

BE

5

70.5

0.7950

BE

5

61.8

0.6460

BE

5

74.5

0.9010

BE

6

67.2

0.7045

BE

6

81.1

0.9826

BE

6

70.5

0.7805

BE

6

85.1

1.0886

BE

1

25.8

0.1221

BEN

1

30.8

0.1647

BEN

2

30.0

0.1453

BEN

2

35.9

0.1960

BEN

2

31.8

0.1883

BEN

2

38.0

0.2540

BEN

2

33.5

0.2313

BEN

2

40.1

0.3120

BEN

2

35.3

0.2743

BEN

2

42.2

0.3700

BEN

3

39.4

0.2976

BEN

3

49.8

0.4014

BEE

3

41.1

0.3406

BEN

3

51.9

0.4594

BEE

3

47.3

0.4266

BEE

3

56.1

0.5754

BE

4

53.1

0.4928

BEE

4

63.2

0.6647

BE

4

56.7

0.5788

BE

4

67.4

0.7807

BE

5

62.5

0.6450

BE

5

74.5

0.8700

BE

5

66.0

0.7310

BE

5

78.7

0.9860

BE

6

71.8

0.7972

BE

6

85.8

1.0753

BE

6

75.4

0.8832

BE

6

90.0

1.1913

BE

Smoke  extraction  dampers  single  are  designed  to  remove  heat  and  combustion  products  (e.g.
smoke) from single fire compartment according EN1366-9.

 

Smoke extraction dampers  single are designed for installation with horizontal or vertical axis of the blades.

 

Backtoback smoke exhaust duct has to be hung or supported so as all load transfer from the  backtoback
smoke 

exhaust 

duct 

to 

the 

damper 

is 

absolutely 

excluded. 

To 

provide 

needed

access  space  to  the  control  device,  all  other  objects  must  be  situated  at  least  350  mm  from  the
control parts of the damper.

During  installation  the  damper  blade  must  be  in  position  CLOSED.  The  damper  body  should
not  be  deformed  in  the  course  of  installation.  Once  the  damper  built  in,  its  blade  should  not  grind
on the damper body during opening or closing.

Example, how to calculate effective area and size of SEDS-L damper [AxB], when knowing  air volume in [m

³

/s] or [m

³

/h] on damper.

Maximum allowed air velocity on SEDS-L is 12 [m/s].

Formula:

Q … air volume [m

³

/s]

Sef … effective free area of damper [m

²

]

v … air velocity on damper [m/s]

Example:

Air volume needed is 26000 m

³

/h

26000 / 3600 = 7,222 m

³

/s

7,222 / 12 = 0,602 m

²

 is min. effective free area [Sef]

Find the value Sef in the table 3.2.1. The effective are has to be the same or bigger. There will be more options of damper, sizes AxB.

Summary of Contents for SEDS-L

Page 1: ......

Page 2: ...on designing ordering delivery maintenance and operation 1 Description 3 2 Design 4 3 Dimensions weights 11 4 Placement and Assembly 13 5 Suspension systems 15 6 Pressure drops 16 7 Noise data 16 8 Ma...

Page 3: ...applications according with EN 1366 9 The field of direct applications based on tests results is acceptable according to EN 1363 1 part A 1 and A 2 EN 1366 2 part 13 and EN 1366 10 part 9 Smoke extra...

Page 4: ...r blade positions is ensured by two built in fixed potential free end limit switches The actuator for operating the damper blade is mounted in an insulated cover box It is accessible after removing th...

Page 5: ...I III II Degree of protection IP 54 Adjustment time for 95 30 s Ambient temperature Storage temperature 30 C 55 C 40 C 80 C Connection drive auxiliary switch Cable 1 m 3 x 0 75 mm2 Cable 1 m 6 x 0 75...

Page 6: ...1 W 3 W 0 3 W 3 5 W 0 4 W Dimensioning 5 VA Imax 8 2 A 5 ms 5 5 VA Imax 8 2 A 5 ms 6 VA Imax 4 A 5 ms Protection class III III II Degree of protection IP 54 Adjustment time for 95 60 s Ambient temper...

Page 7: ...in the end position 12 W 0 5 W 8 W 0 5 W Dimensioning 18 VA Imax 8 2 A 5 ms 15 VA Imax 7 9 A 5 ms Protection class III II Degree of protection IP 54 Adjustment time for 95 60 s Ambient temperature Sto...

Page 8: ...30 24 controls the switching position of the actuator its adjustment time and the data exchange with the BKSE 24 6 In addition it controls the actuator current actuator connection and the power supply...

Page 9: ...work drive terminal blocks cable 1 m without plug 6 pin plug 3 pin plug screw terminals for 2x1 5 mm2 conductor yellow flashing damper rotates to the open position yellow lit up damper is open green f...

Page 10: ...valuated separately All BKNE 230 24 are controlled simultaneously A maximum of 6 BKNE 230 24 can be connected to the BKSE 24 6 Damper control is ensured with a simple 2 wire line The damper s correct...

Page 11: ...11 1 Damper body 2 Damper blade 3 Actuating mechanism cover Dimensions mm mm BEN BEE 176 5 315 BE 186 5 380 BEN BEE BKNE 236 5 315 BE BKNE 251 5 380 standard height of the flange...

Page 12: ...44 5 0 3075 BEE 5 38 5 0 1785 BEE 5 47 0 0 3485 BEE 6 41 6 0 1947 BEE 6 50 9 0 3801 BEE 6 43 6 0 2157 BEE 6 53 4 0 4211 BEE 1 15 9 0 0369 BEN 1 19 2 0 0653 BEN 2 18 3 0 0439 BEN 2 22 2 0 0777 BEN 2 19...

Page 13: ...53 1 0 4928 BEE 4 63 2 0 6647 BE 4 56 7 0 5788 BE 4 67 4 0 7807 BE 5 62 5 0 6450 BE 5 74 5 0 8700 BE 5 66 0 0 7310 BE 5 78 7 0 9860 BE 6 71 8 0 7972 BE 6 85 8 1 0753 BE 6 75 4 0 8832 BE 6 90 0 1 1913...

Page 14: ...1 Damper hinge 2 Nut 3 Washer 4 Profile C 5 Washer C 6 Wall construction without fire resistance 7 Atypical protection box with access to actuator from side not as standard from the top Installation...

Page 15: ...234 M20 245 150 300 Position 1 Threaded rod M8 M20 2 Nut 3 Washer 4 Coupling Nut 5 Anchor 6 Hinge plate min thickness 10 mm 7 Concrete screw tested for fire resistance R30 R90 max Tension up to 0 75...

Page 16: ...63 68 68 67 65 62 48 57 65 70 70 69 67 64 50 w air velocity in the free cross section AxB i e before blades f frequency of octave band Sound power level corrected with filter A ps static pressure drop...

Page 17: ...67 65 62 48 w air velocity in the free cross section AxB i e before blades f frequency of octave band 13 21 26 26 25 23 20 6 21 29 34 34 33 31 28 14 28 36 41 41 40 38 35 21 34 42 47 47 46 44 41 27 38...

Page 18: ...re must be in the range from 5 C to 40 C and maximum relative humidity 80 Dampers must be protected against mechanic damages when transported and manipulated All effective safety standards and directi...

Page 19: ...ith cables from actuator acc to above mentioned electrical diagram Seal up the space around cable with fire resistant mastic HILTI CFS S ACR PROMASTOP or equivalent Let the mastic harden Drill two hol...

Page 20: ...o ensure that the damper is put into condition in which it is ready for function and meanwhile he is obliged to provide the fire protection by another appropriate way Results of regular checks imperfe...

Page 21: ...tuating mechanism BEN BEE BE for 230V 44 with actuating mechanism BEN BEE BE for 24V 54 with actuating mechanism BEN BEE SR for 24V 65 with the communication and supply device BKNE 230 24 and actuatin...

Page 22: ...reserves the right for innovations of the product For actual product information see www mandik com MAND K a s Dob sk 550 26724 Hostomice Czech Republic Tel 420 311 706 706 E Mail mandik mandik cz ww...

Reviews:

Related manuals for SEDS-L