SAFETY INSTRUCTIONS 

Please  take  care  of  the  following  basic  safety  procedures  when  mounting,  starting  up  or 
operating this equipment:  
 

Read  this  operating  manual  before  starting  up  and  use  of  the  equipment.  The  information  and 
warnings given in this operating manual must be heeded.   
 
Any work on electrical equipment is only to be carried out by trained specialists as per the regulations 
currently in force.  
 
Attention must be paid to the requirements of VDE 0100 (IEC 364) when setting high-power electrical 
units with nominal voltages of up to 1000 V, together with the associated standards and stipulations.  
 
Check  the  details  on  the  type  plate  to  ensure  that  the  equipment  is  connected  to  the  correct  mains 
voltage.  
 
Protection against touching dangerously high electrical voltages:  
Before opening the equipment, it must be switched off and hold no voltages. This also applies to any 
external control circuits that are connected.  
 
The device is only to be used within the permitted range of temperatures and pressures.  
 
Check that the location is weather-protected. It should not be subject to either direct rain or moisture.  
 
The pump must not be used in hazardous areas.   
 
Installation, maintenance, monitoring and any repairs may only be done by authorized personnel with 
respect to the relevant stipulations. 
 
 
 

WARRANTY 

If the equipment fails, please contact 

M&C 

directly or else go through your 

M&C 

authorised dealer. 

We offer a one year warranty as of the day of delivery as per our normal terms and conditions of sale, 
and assuming technically correct operation of the unit. Consumables are hereby excluded. The terms 
of the warranty cover repair at the factory at no cost or the replacement at no cost of the equipment 
free ex user location. Reshipments must be send in a sufficient and proper protective packaging. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MP Series

Page 1: ...Analytical Diaphragm Pump Series MP MP30 Instruction Manual Version 1 00 01...

Page 2: ...sses are to be found in the annexe to this operating manual Please also contact our homepage www mc techgroup com for further information about our products There you can read or download the data she...

Page 3: ...ata 9 9 Dimensions 10 10 Receipt and storage 10 11 Installation information 10 11 1 Mechanical 11 11 2 Electrical 11 11 3 Pneumatic 12 12 Commissioning 13 13 Decommissioning 14 14 Maintenance 14 14 1...

Page 4: ...riate transportation correct storage as well as professional installation and maintenance work All necessary information a skilled staff will need for appropriate use of this product are given in this...

Page 5: ...re opening the equipment it must be switched off and hold no voltages This also applies to any external control circuits that are connected The device is only to be used within the permitted range of...

Page 6: ...minor physical injuries may occur in case the respective safety measures are not fulfilled C AR E Without the warning triangle means that a material damage may occur in case the respective safety mea...

Page 7: ...on proof design The MP30 has a delivery capacity of 7 5l min at atmospheric pressure The output on the pressure side is limited to maximum 2 5 bar absolute Application examples are Transport of gases...

Page 8: ...not be used in areas subject to explosion hazards or for transporting a potentially explosive medium When transporting toxic media system specific and safety relevant regulations must be observed MAC...

Page 9: ...0 Delivery capacity max 7 5 l min Operating pressure 0 14 to max 2 5 bar abs Gas temperature 5 C to 40 C Ambient temperature 5 C to 40 C Storage temperature 15 C to 60 C Gas connections G1 8 i DIN ISO...

Page 10: ...ceipt and check the delivery against the delivery note Check the contents for possible transport damage and immediately notify the transport insurer of any damage NOTE The diaphragm pump should be sto...

Page 11: ...s must be installed in such a way that the impeller is able to draw in sufficient cooling air The pumps should be installed at the highest point in the system and or with the pump head pointing downwa...

Page 12: ...hose couplings the following should be noted NOTE The tightness of the connection can only be ensured when the connecting hose has a straight terminating edge use of a hose cutter Loosen the swivel n...

Page 13: ...king pressure of the pump is not exceeded With the pump stationary normal atmospheric pressure must be established in the pipes Diaphragms and valve plates are the only wearing parts of the pumps Wear...

Page 14: ...process specific safety measures must be observed W AR N I N G Dangerous voltage Before working on the diaphragm pump the same must be safely isolated from the supply and disconnection from the suppl...

Page 15: ...making a continuous line with a felt tip pen Loosen four head screws 5 Remove pressure plate 15 head cover 4 and intermediate plate 1 from pump housing Loosen four fixing screws in impeller cover 13 a...

Page 16: ...on by lightly moving the valve seat Fit sealing rings 3 in intermediate plate 1 Join head cover 4 and intermediate plate 1 together felt tip pen mark must be in alignment and check centred seat throug...

Page 17: ...rheating Delivery capacity pressure or vacuum too low Diaphragms or valve plates worn Replace worn parts see 14 ff Problem Indication Possible cause Check Remedy Initially compare reached pump capacit...

Page 18: ...nd on specific operating conditions The recommended quantities are based on experience and are not binding Diaphragm Pump Type MP30 C consumable parts S spare parts Recommended quantity MP30 being in...