Please consider following boundary conditions for
the SCR operation:
▪
Temperature control of temperature turbine out-
let:
– By adjustable waste gate (attached to
engine).
– Set point 320 °C as minimum temperature
for active SCR.
– Set point 290 °C as minimum temperature
for deactivated SCR.
▪
Fuel:
– In line with MAN Diesel & Turbo specifica-
tion, maximum 3.5 % sulfur content.
▪
SCR active in following range:
– 10 °C (arctic) up to 45 °C (tropic) intake air
temperature.
– In the range of 25 % to 100 % engine load.
▪
IMO requirements for handling of SCR opera-
tion disturbances:
– In case of SCR malfunction IMO regulations
allow that the system will be turned off and
the ship's journey will be continued to the
port of destination. There, the ship needs to
be repaired, if the emission limits of the har-
bor/sea area would be exceeded.
Accordingly, the vessel may leave a port in
case it will only sail in areas requiring IMO II,
even if the SCR system is still out of service.
▪
Differential pressure Δp SCR (normal operation):
– Max. 20 mbar.
For the design of the complete exhaust gas line,
please consider:
▪
Maximum permissible exhaust gas back pres-
sure (to be calculated from engine turbocharger
outlet to end of complete exhaust gas line):
– Max. 50 mbar (at 100 % engine load).
▪
Maximum permissible temperature drop of
exhaust gas line (to be calculated as difference
of exhaust gas temperature turbine outlet and
temperature SCR inlet):
– Max. 5 K in the range of 25 % to 100 %
engine load (calculated at 5 °C air tempera-
ture in the engine room).
▪
Recommended for exhaust gas line:
– Insulation according to SOLAS standard.
The SCR system requires high exhaust gas tem-
peratures for an effective operation. MAN Diesel
& Turbo therefore recommends to arrange the
SCR as the first device in the exhaust gas line,
followed by other auxiliaries like boiler, silencer
etc.
▪
Performance guarantee for engine plus SCR
within defined in section Boundary conditions
for SCR operation.
▪
Guarantee for engine plus SCR for marine appli-
cations to meet IMO Tier III level as defined by
IMO within defined in section Boundary condi-
tions for SCR operation (details will be handled
within the relevant contracts).
Please be aware
All statements in this document refer to MAN
Diesel & Turbo SCR systems only.
MAN Diesel & Turbo can only deliver an IMO Tier
III certificate and act as “Applicant” (within the
meaning of the IMO) if the engine plus SCR sys-
tem is supplied by MAN Diesel & Turbo.
If the engine is supplied without MAN Diesel &
Turbo SCR system, only a standard warranty for
a single engine will be given. No guarantee
regarding minimum exhaust gas temperature
after turbine or emissions after third party SCR or
suitability of the engine in conjunction with a third
party SCR system can be given.
If the engine is supplied without MAN Diesel &
Turbo SCR system, no optimisation function
within SaCoS can be applied and as maximum
exhaust gas temperature after turbine only will be
possible:
▪
320 °C (25 % load – 100 % load).
MAN Diesel & Turbo
B1600 0
SCR (Selective Catalytic Reduction)
3700467-8.1
Page 4 (17)
V28/32S, L28/32S, L28/32H, L27/38S, L27/38, L23/30S, L23/30H, L21/31S,
L21/31, L16/24S, L16/24
Summary of Contents for L23/30DF
Page 1: ...L27 38S Project Guide Power Plant Four stroke GenSet...
Page 2: ......
Page 8: ......
Page 9: ...MAN Diesel Turbo I 00 Introduction Page 1 1 I 00 Introduction 2018 04 13 en...
Page 10: ......
Page 14: ......
Page 16: ......
Page 20: ......
Page 31: ...MAN Diesel Turbo D 10 General information Page 1 1 D 10 General information 2018 04 13 en...
Page 32: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 50: ......
Page 59: ...MAN Diesel Turbo B 10 Basic diesel engine Page 1 1 B 10 Basic diesel engine 2018 04 13 en...
Page 60: ......
Page 68: ......
Page 70: ......
Page 72: ......
Page 74: ......
Page 76: ......
Page 82: ......
Page 84: ......
Page 85: ...MAN Diesel Turbo B 11 Fuel oil system Page 1 1 B 11 Fuel oil system 2018 04 13 en...
Page 86: ......
Page 104: ......
Page 114: ......
Page 118: ......
Page 126: ......
Page 128: ......
Page 130: ......
Page 134: ......
Page 138: ......
Page 142: ......
Page 173: ...MAN Diesel Turbo B 13 Cooling water system Page 1 1 B 13 Cooling water system 2018 04 13 en...
Page 186: ......
Page 192: ......
Page 198: ......
Page 202: ......
Page 204: ......
Page 207: ...MAN Diesel Turbo B 14 Compressed air system Page 1 1 B 14 Compressed air system 2018 04 13 en...
Page 210: ......
Page 216: ......
Page 217: ...MAN Diesel Turbo B 15 Combustion air system Page 1 1 B 15 Combustion air system 2018 04 13 en...
Page 218: ......
Page 224: ......
Page 226: ......
Page 227: ...MAN Diesel Turbo B 16 Exhaust gas system Page 1 1 B 16 Exhaust gas system 2018 04 13 en...
Page 228: ......
Page 252: ......
Page 256: ......
Page 269: ...MAN Diesel Turbo B 17 Speed control system Page 1 1 B 17 Speed control system 2018 04 13 en...
Page 270: ......
Page 272: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 293: ...ENGINE AUTOMATION MAN Diesel Turbo SE SaCoSone GENSET System description Revision 1 5...
Page 306: ...MAN Diesel Turbo SaCoSone GENSET SaCoSone GENSET Communication from GenSet Revision 1 7...
Page 309: ...MAN Diesel Turbo Table of Contents...
Page 324: ......
Page 326: ......
Page 327: ...MAN Diesel Turbo B 20 Foundation Page 1 1 B 20 Foundation 2018 04 13 en...
Page 328: ......
Page 334: ......
Page 335: ...MAN Diesel Turbo B 21 Test running Page 1 1 B 21 Test running 2018 04 13 en...
Page 336: ......
Page 341: ...MAN Diesel Turbo E 23 Spare parts Page 1 1 E 23 Spare parts 2018 04 13 en...
Page 342: ......
Page 348: ......
Page 350: ......
Page 351: ...MAN Diesel Turbo P 24 Tools Page 1 1 P 24 Tools 2018 04 13 en...
Page 379: ...MAN Diesel Turbo B 50 Alternator Page 1 1 B 50 Alternator 2018 04 13 en...
Page 380: ......
Page 386: ......
Page 390: ......
Page 392: ......