Control and operation
65
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
9.1.1
Operating engine from engine room (classified)
Starting the engine
► Voltage supply active at X1
► Switch on system at ON/OFF button (1)
► Transfer of command to local operator's stand
by pressing the “Local” button (2)
► Confirm command via “Local ON” button of the
engine room display AL
► Start the engine by pressing the “Engine Start”
button on the engine room display AL
For other control commands see display functions
of the engine room display of the E-box, from
page 69.
Transfer of command from Local to an operator's stand
Press the “Remote” button (1) to make the
command request from the engine room to the
operator’s stand of the ship. The command
request must be confirmed via the correct drive
lever control unit, see next page.
Transfer of command from Remote to Local
Press the “Local” button (2) to make the command
transfer from the operator's stand of the ship to the
engine room.
Command hierarchy
The design of the system stipulates that the engine room has command authority over the engine.
Therefore, command can be transferred into the engine room from an operator's stand by pressing the
“Local” button.
S
If operation of the engine is activated from the engine room, command can
only be transferred from the
engine room
to the operator's stand.
S
If operation of the engine is activated from an operator's stand, command can be
taken over by the
engine room
.
Summary of Contents for iSea