Commissioning and operation
39
2. Command request:
The command can be requested at any control stand. The control levers of the command
master on the requesting control stand must be set at the “Neutral position”.
.
“Command master calibration and enable of control stands” must have been carried
out. Otherwise, the command can only be taken over at control stand 1.
Execution:
– Set the control lever of the command master to the “Neutral position”.
– Press “Command” key once for command request.
Consequence: – Display “Alarm” (red) on all control stands remains lit up continuously.
– Acoustic signal transmitter sounds with fast intermittent tone on all
control stands.
– The display “Command” flashes rapidly.
.
If the control system continues to issue long lighting and tone intervals, it is usually the
case that the control lever of a command master is not in the “Neutral position”.
3. Command takeover:
Execution:
– Press “Command” key once again for confirmation
of command request.
Consequence: – Display “Alarm” (red) goes out on all control stands.
– Acoustic signal transmitter remains silent on all control stands.
– “Command” display shows continuous light on the command
master in command.
On all other command masters, the “Command” display is off.
The command is now at this control stand. The control system is ready for operation
(standby).