When the air purifier no longer produces enough ozone to be effective, the ozone 

plate should be cleaned (unless it has burnt spots, then the ozone plate should be 

replaced).  A good rule of thumb is to clean the ozone plate  every month if used 

continuously. 

To clean the ozone plate, first turn the unit OFF and UNPLUG from outlet.  Then 

remove  the  ozone  plates  from  back  of  unit.    Pull  plates  firmly  in  the  center  to 

remove from the slot.  With plate firmly supported in the hand apply a solution of 

warm water and ammonia (50/50 solution is suggested) or a strong grease cutting 

detergent.  Scrub with a stiff brush if necessary.  Be careful not to drop the plate or 

scrub off the silicon.  Clean both the metal screen and the ceramic tile.  Rinse plate 

in hot water and DRY COMPLETELY before installing.  If available you may use a 

hair dryer to dry the plate.  Reinstall plate, making sure it is secured and flush with 

the back of the unit.  

If the ozone generator is making excessive noise or excessive sparks is visible, 

ozone plate should be replaced (even if no burnt mark is present). 

To clean needlepoint ionizer, first turn OFF and UNPLUG from outlet.  Remove 

the fan grill cover.  The needle point ionizer will be easy to find in front of the fan 

by looking for two pieces of wire.  Take a q-tip or cotton swab dipped in alcohol 

and clean any dust that may have accumulated on the needlepoints.  This process 

may be done when plates are being cleaned.  While you have the front grill cover 

off the unit you may also clean the fan and grill itself.  To clean the fan, simply 

wipe the blades with a damp cloth or vacuum.  The grill cover may also be cleaned 

with warm soapy water.  Be careful that the fan grill cover is completely dry before 

installing.

To clean the pre-filter, simply wipe down the surface to remove all the bigger 

particles.  Do not rise the filters as water will damage the HEPA and Carbon filter 

inside.  If the Mammoth Classic Air Purifier is continuously ON, replace filter every 

6 months.  The replacement filter can be purchased at an affordable price at www.

mpurifier.com or call (800) 470-4201.  

NOTE: If you have purchased extra replacement filter in advance, keep the filter 

in the original packaging since exposure to open air will start the life cycle of the 

air filter.  

CLEANING AND MAINTENANCE

Summary of Contents for Classic

Page 1: ...For Air as Pure as the Ice Age ClassicTM Air Purifier USER GUIDE R ...

Page 2: ... or lack of experience and knowledge unless they have been given supervision concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit CAUTION TO REDUCE THE RISK OF ELECTRICALSHOCK DO NOT REMOVE BACK COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL This EXCLAMATION POINT calls...

Page 3: ...pe that you will enjoy your purchase for years to come READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT Please record the serial number and information below for easy reference These numbers are located on the back panel of your air purifier These information will help with warranty request Model number Mammoth ClassicTM Air Purifier Serial Number ________________________________________ ...

Page 4: ...it before removing PART FUNCTION Ionizer Prong Front Grill Control for the negative ion generator is separate from the O3 control Negative ions can be created around the clock to keep down dust and particulate O3 also known as ozone can be used at modest levels in occupied spaces To remove heavy odor turn the dial clockwise to increase O3 production for a short period of time Another way to use th...

Page 5: ...e dry completely before replacing If burnt replace IceTechTM HEPA Filter HEPA filter can be replaced by taking off the screws HEPA Combined filter filters 99 97 particles smaller than 0 3 micron Under continuous use replace every 6 months IceTechTM Carbon The Carbon filter absorbs contaminants in the air Filter Combined such as gasses and odors The Carbon filter is attached to the HEPA filter UV I...

Page 6: ...cation on a counter top shelving or any space above ground Since ozone is heavier than air elevated placement will allow for more effective usage of ozonator If you must there is no problem with the air purifier on the floor or in the corner of the room Always allow at least three inches of space between the back and the side of the unit from the wall or other objects to allow for proper airflow s...

Page 7: ...zone production and is on automatically when the fan is on The ionizer can be used around the clock to keep dust and particulate at bay Individual sensitivity to O3 and preference may vary and should be adjusted accordingly The effect of O3 on indoor air may vary according to atmospheric and or environmental conditions such as altitude humidity air movement and severity of existing odors house des...

Page 8: ...l air through the air purifier Decreases viruses and unhealthy bacteria from the surroundings therefore lessening the growth of ailments like pneumonia tuberculosis and other sicknesses Reduces the risk of allergies bacterial or viral infections hay fever and respiratory problems to some extent Something to keep in mind everyone interacts with ozone differently it is recommended that the ozone fea...

Page 9: ...d off Homes Living Areas All types of offices stores Water fire damaged areas New paint wallpaper areas Odor clean up Sick buildings Hospitals nursing homes Veterinary offices Smoking areas Hotel rooms Should you determine that your air unit requires service please contact your Mammoth Air Purifier CAUTION No attempt should be made to remove the back panel of the unit as there are no user servicea...

Page 10: ...visible ozone plate should be replaced even if no burnt mark is present To clean needlepoint ionizer first turn OFF and UNPLUG from outlet Remove the fan grill cover The needle point ionizer will be easy to find in front of the fan by looking for two pieces of wire Take a q tip or cotton swab dipped in alcohol and clean any dust that may have accumulated on the needlepoints This process may be don...

Page 11: ... not burned out To replace fuse push in and turn fuse holder to the left remove old fuse replace with spare Use 1 amp fuse 1 25 inches long Wall outlet is active Check plate alignment making sure the ceramic plate is almost flush with back of unit It is important that the ClassicAir Purifier be properly grounded to avoid potential shock If the fan is not operating or after cleaning the plate no bu...

Page 12: ...dings we spend most of our time in block out the natural occurring negative ions The Classic Air Purifier recreates the natural balance of positive to negative ions to significantly reduce airborne particulate 2 This Purifier uses electricity to split oxygen O2 molecules into single Oxygen atoms which attach loosely to other O2 molecules to become O3 activated oxygen This loosely attached oxygen a...

Page 13: ...r will be completely saturated and the photocatalytic property will be depleted Without changing the filter every 6 months the efficiency of the air purifier will decrease dramatically and very inefficient Mammoth offers industry cheapest replacement filters all in one combo Q IS THE PURIFIER DIFFICULT TO INSTALL A No the Classic Air Purifier is easy to set up For use without O3 the air purifier i...

Page 14: ...4pm PST Call 800 470 4201 or e mail support mpurifier com Thank you for your business Your family and loved ones will be enjoying fresh air in the years to come MAMMOTH AIR PURIFIER StarKnight Inc 23755 Madison Street Torrance CA 90505 www mpurifier com 800 470 4201 ...

Reviews: