MAMAC SYSTEMS TE-703 Technical Information Download Page 4

Model  TE-703/704

Technical Information

TI.703/704-03

PIPE TEMPERATURE SENSORS

Page 4 of 4

TI.703/704-03

RoHS

Figure 8

TE-704-C & TE-704-D

For complete 

Resistance Versus Temperature 

tables, please refer to TI.700-11.

4.00"

(100 mm)

5.00"

(124 mm)

2.00"

(50 mm)

2.50"

(62 mm)

3.50"

(90 mm)

4.30"

(110 mm)

For Technical / Application Assistance call your nearest office

8189 Century Boulevard • Minneapolis, MN 55317-8002 • USA

800-843-5116 • 952-556-4900 • Fax 952-556-4997

[email protected] • www.mamacsys.com

EUROPE

4200 Waterside Centre

Solihull Parkway

Birmingham • West Midlands

B37 7YN • United Kingdom

01384-271113 • Fax 01384-271114

AUSTRALIA

4 Armiger Court, Unit 2

Adelaide • S.A.

5088 • Australia

08-8395-4333 • Fax 08-8395-4433

CANADA

675 Cochrane Drive

East Tower • 6th Floor

Toronto • Ontario

L3R 0B8 • Canada

905-474-9215 • Fax 905-474-0876

ASIA

1 Fullerton Road #02-01

One Fullerton

Singapore • 049213

65-31581826 • Fax 65-31581826

MAMAC Systems, Inc., reserves the right to change any specifications

without notice to improve performance, reliability, or function of our products.

Summary of Contents for TE-703

Page 1: ...sure NEMA 1 IP 30 D Painted Steel Enclosure NEMA 4 IP 65 A 4 100 mm B 6 150 mm C 8 200 mm 1 100 Ohm Platinum RTD 2 1 000 Ohm Nickel RTD 5 000 PPM 3 1 000 Ohm Platinum RTD 4 1 000 Ohm Nickel RTD 6 000 PPM 5 1 000 Ohm Balco RTD 7 10 000 Ohm NTC Thermistor Type III 8 10 000 Ohm NTC Thermistor Carel 10 3 000 Ohm NTC Thermistor 12 10 000 Ohm NTC Thermistor Type II 13 5 000 Ohm NTC Thermistor 14 1 035 O...

Page 2: ... that it makes contact with the pipe and fasten with two pipe clamps not provided 4 Loosen the cover screws and rotate the cover out of the way 5 Make the wiring connections Rotate and screw the cover back into place Figure 1 Installing the Immersion Sensor Figure 2 Installing the TE 704 A Sensor Inspection Requirements INSTALLATION Inspect the package for damage If damaged notify the appropriate ...

Page 3: ...erature Sensor section 4 Reconnect sensor lead wires to the controller 5 Check operation of the complete control system Figure 3 Installing the TE 704 B TE 704 C or TE 704 D Sensor MAINTENANCE Regular maintenance of the total system is recommended to assure sustained optimum performance FIELD REPAIR None Replace with a functional unit DIMENSIONAL DATA TE 703 704 Pipe Temperature Sensors dimensions...

Page 4: ...556 4900 Fax 952 556 4997 sales mamacsys com www mamacsys com EUROPE 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384 271113 Fax 01384 271114 AUSTRALIA 4 Armiger Court Unit 2 Adelaide S A 5088 Australia 08 8395 4333 Fax 08 8395 4433 CANADA 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905 474 9215 Fax 905 474 0876 ASIA 1 Fullerto...

Reviews: