Reset Feature
If the alarm is sounding, pressing the button will silence the alarm for several minutes.
After the duration, if the CO condition that caused the alert continues, the alarm will
reactivate. If the CO level keeps from 70ppm to 200ppm, the duration is around 5 minutes.
If the CO level keeps over 200ppm, the duration is zero, i.e. the unit will sound soon. If the
CO level keeps below 70ppm, the unit will not reactivate longer.
Alarm Memory Feature
If you leave home for long time and during the period the unit ever alarms, after you return
and press the button for several seconds, green LED will flashes once every seconds and
the peak alarm level will indicate on the LCD to alert you there is one CO alarm occurs.
You should check the possible CO source and resolve it. Pressing the button again, the
unit will return to normal condition or return to normal condition in one minute
automatically.
LED indicator Operation
Red LED
Red Led will flash in conjunction with the alarm beep. Therefore, the red LED will flash
during a CO alarm, a l ow battery mode chirp and a malfunction status.
As you install the battery on the unit, the unit will sound ‘chirp’ to indicate the
battery installed properly.
Green LED
Green LED flashes once every 30 seconds to indicate proper operation and it is out to
indicate malfunctioning.
What To Do IF The Alarm Sounds
IF alarm sounds:
1. Call your emergency services.
2.
Immediately move to fresh air – outdoors or by an open door/window. Do a head
count to check that all persons are accounted for. Do not re-enter the premises nor
move away from the open door/window until the emergency services responders
have arrived, the premises have been aired out, and your alarm remains in its
normal condition.
Never restart the source of a CO problem until it has been fixed. NEVER IGNORE
THE ALARM!
The CO sensor sensitivity and setting is:
30ppm, alarms within 120 minutes
50ppm, alarms within 60~90 minutes
100ppm, alarms within 10~40 minutes
300ppm, alarms within 3 minutes
This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY
source of combustion. It is not designed to detect any other gas.
Fire departments, most utility companies will perform CO inspections, some may charge
for this service.
Battery Replacement
If battery failure is detected the unit will “chirp” one time. This cycle will occur once every
30 seconds.
CAUTION: YOUR ALARM IS SEALED AND THE COVER IS NOT REMOVABLE!
12/22