![MALTEC PT3800Wt Instruction Manual Download Page 18](http://html1.mh-extra.com/html/maltec/pt3800wt/pt3800wt_instruction-manual_3943611018.webp)
temperatu
re
On
heating.
Press “+”,
Set temperature is 1-2
℃
higher than Environment temperature, Low
heating.
Set temperature is higher or equal to Environment temp3
℃
, High
heating.
2
、
Press OK, or after LED flickering 5s, set temperature mode is start up.
Open
window
detection
Open
window
detectio
n
Light
flickerin
g
1
、
Open window detection only can be start up when appliance in
heating mode(can not start up when appliance is only fan working) or in
set temperature mode.
2
、
Press “
”,
Open window detection on, Open window detection off.
3
、
Temperature detection start up after 1 minute from Open window
detection start up.
Per 10 minutes(temperature slow down detection check point) as a round,
in one round, detect the temperature once every 5 minutes(temperature
fast down detection check point). Detail in the following table.
Time round
Min: s
Time
Min: s
Description
00:00 - 01:00
0:00
Open window detection start up
01:00-11:00
1:00
Temperature detection start up
Temperature detection starting
check point
6:00
Temperature detection check point 1
(temperature fast down detection check
point).
1
、
Temperature detection check
point 1 reduce from Temperature
detection starting check point
≤
8 , the appliance keep
℃
heating
and Open window detection keep
working.
2
、
Temperature detection check
point 1 reduce from Temperature
detection starting check point >
8
℃
.
The appliance stop heating
and stand by, Open window
detection stop.(See Remarks)
3
、
Temperature detection check
point 1
(
**
℃)
≥
Temperature
detection starting check point, the
appliance keep heating and Open
window detection keep working
**
℃
:
Maximum detection
temperature 51
℃
(See power-off
protection)
18/38