3.2 SWITCH OFF
To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down
and then turn the fan switch to position O.
3.3 AIR CONDITIONING
a. The heater can also be used as a ventilator.
b. In this case remove the gas supply hose and connect the plug of heater to a suitable
electrical supply.
c. Set the fan switch to position I.
ODOR FADE WARNING
!
!!
WARNING
Asphyxiation Hazard
Do not use heater for heating human quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be obstructed.
Proper ventilation air must be provided to support the combustion air requirements of the
heater being used.
Lack of proper ventilation air will lead to improper combustion.
Improper combustion can lead to carbon monoxide poisoning leading to serious injury or
death. Symptom of carbon monoxide poisoning can include headaches dizziness and
difficulty in breathing.
FUEL GAS ODOR
LP gas and natural gas have man-made odors added specifically for detection of
fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is
heavier than air you should smell for the gas odor low to the floor.
ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
1. Do not take any action that could ignite the fuel gas. Do not operate any electrical
switches. Do not pull any power supply or extension cords. Do not light matches or any
other source of flame. Do not use your telephone.
2. Get everyone out of the building and away from the area immediately.
3. Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply
valve located at the meter if you use natural gas.
4. Propane (LP) gas is heavier than air and may settle in low areas. When you have
reason to suspect a propane leak, keep out of all low areas.
5. Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do
not reenter the building or area.
6. Stay out of the building and away from the area from the area until declare safe by the
firefighters and your fuel gas supplier.
7. FINALLY, let the fuel gas service person and the firefighters check for escaped gas.
Have them air out the building and area before you return. Properly trained service
people must repair any leaks, check for further leakages, and then relight the appliance
for you.
4. MAINTENANCE
4.1. The repairs or maintenance operations must only be carried out by qualified
personnel.
4.2. The unit must be checked by a qualified technician at least once a year.
18/20