1.17 Heaters described in this leaflet are not intended for domestic use.
1.18 In the case that a gas leak is found or suspected, immediately close the gas
cylinder, switch the heater off and do not use it again until it has been checked by a
qualified service center. If the heater is installed indoors, provide a good ventilation by
opening door and windows completely. Do not produce sparks or free flames.
1.19 If in any doubt contact your supplier.
2. INSTALLATION
2.1 Connect the heater to a suitable electric socket /230V~50Hz
2.2 Make sure that the machine is properly earthed.
2.3 Connect the gas supply hose to the pressure regulator and connect the regulator to a
suitable LPG cylinder.
2.4 Open the tap of the cylinder and check the supply hose and fittings for gas leak. For
this operation it is recommended to use an approved leak detector.
2.5 NEVER USE NAKED FLAMES.
2.6 For automatic appliances, connect the room thermostat to the socket on the appliance
and adjust it to the required temperature.
3. INSTRUCTION FOR USE
PREPARING FOR OPERATION
6. Check the heater for possible shipping damage.
7. Connect the hose and regulator assembly to the LPG cylinder by rotating the nut
counterclockwise into the LPG cylinder’s valve outlet and securely tighten.
8. Open the cylinder’s gas valve and check all gas connections with a soap and water
solution.
9. Connect power cord to well-grounded 220V~, 50Hz source of power.
3.1 IGNITION
3.1.1 IGNITION /automatic ignition
a. Turn the power switch to position I and motor start working. The digital display window
shows the room temperature.
Figure.2
b. Open the valve and turn the power switch to II. The left display window is setting
temperature and right one is room temperature. It would ignite automatically when the
setting temperature is higher than room.
16/20