![background image](http://html2.mh-extra.com/html/malmet/wds/wds_operation-maintenance-and-installation-manual_3919755041.webp)
WDS
Operation, Maintenance and Installation Manual
ISSUE 5
Page
41
15/03/2016
Nozzles and Sprays
Flush nozzles
2 x Rotary Nylon
Tip Sprays
2 x WL1/2 120° 1/8 bsp ss
Top Sprays
4 x WL1/4 90° 1/8 bsp ss
Bottom sprays
4 x WL1/2 60° 1/8 bsp ss
Urine Bottle sprays
4 x WL1/4 90° 1/8 bsp ss
Cool Down sprays
2 x LW1 120° 1/4 bsp ss
Wash pump
Horizontal multistage
750W 240V 1ph 4.6A
116.7L/Mins
s/s impeller and housing
Detergent
Malmet specific (5Lt)
Detergent Concentrate
Caustic Alkaline
ARTGC Class 1
Detergent pump
Self priming peristaltic
Chemical feed pump
72 rpm 240V 50Hz
PLUMBING
Soil line Connection
Type
‘S’ or ‘P’ Trap (6mm PE) 80°
Complies to AS 2887 &
AS/NZS 3500.2:2003
Size
100mm ID
Backflow Prevention
Air Gap (RAG)
Water storage tank
AS 2845.2 - 1996
Cold water inlet Supply
Temp – Pressure (Flow)
15 – 25°C @ 100 – 350kpa
Solenoid Valve 1 in 2 out
240V - GB¾ male
WRAS Certified
Hot Water inlet supply
Temp – Pressure (Flow)
55 – 60°C @ 100 – 350kpa
Solenoid Valve 1 in 1 out
240V - GB¾ male
WRAS Certified
Minimum water flow @ 100 Kpa
9.377 L/min
Hose – valve to Water Tank
S/steel Braided
10mm
WRAS Certified
Hoses – Mains Water Supply to
Inlet Valve
S/steel Braided Assy H/C
Water
G¾ Hex Nut Each End
1.5M x 10mm
Cert to AS/NZS 3499-
2006
CONSTRUCTION MATERIALS
Materials
Frame
25 x 25 x 1.6 tube s/steel
Wash chamber
316 S/S grade 4
Door
316 S/S grade 4
External panels
304 S/S grade 4
Water tank
316 S/S grad 2B
Steam generator
316 S/S grade 2B
Fasteners
304/316 S/S
Thermal insulation
chamber and water tank
TBA
ENVIROMENTAL
Environment conditions
Transport and Storage
Fragile
Keep away from rain
Do not stack
Temperature
-5°C to +50°C
Environment operating
conditions
Temperature
+10°C to +25°C
Relative Humidity
+30% to 75%
Shipping details
Height x Width x Depth
1770 x 800 x 750
Weight = Pac Det