5.9 USER MENU AND TEST MODE
After normal Power On mode (not restart attempt), the operator can place the system into the MENU and test
mode.
To Enter the MENU model, press ENTER and simultaneously press SCROLL and hold for 5 seconds.
The display will show “MENU”
5.9.1
MENU LEVELS
Once into the menus, the SCROLL and SELECT / ENTER buttons generally become operative with the
LCD displays in following way:
For LEVEL 0 and LEVEL 1
The SCROLL button moves the selection down within the Same Level.
The SELECT button the selects the option and moves to the next level down the chain
Pressing SELECT on the EXIT option moves the selection back up to the previous higher level
At the SELECT Level
The SCROLL button moves the selection down within the Same Level.
For incrementing fields SCROLL behaves as follows:
Short Press SCROLL – increments (or decrement) at slow rate 1 per second
Hold SCROLL (> 1 second) increments (or decrement) at fast rate 5 per second
Long Break (>5 second) reverses direction
The SELECT button then selects and SAVES the option and moves back up to previous higher level.
The table below indicates the Text displayed in the 7 Char Text Display Field
LEVEL 0 – just shows the Level Text
LEVEL 1 – alternates the Level 1 Text with the Current Set Value in the SELECT field
A general timeout of 180 seconds for no buttons pressed will EXIT the menus and return to the main
POWER OFF state.
LEVEL 0
LEVEL 1
SELECT
COMMENTS
(MENU changes to parameters are stored to EEROM)
MENU
BACKLIT
0(OFF) to 12(Max)
HANDS
OFF/ON
Option to disable H/Free Not Yet Available
USEHOT
OFF/ON
Option to Disable Hot Water Filling
BUZZER
ALL
ON/OFF
KEYS
ON/OFF
HAND
ON/OFF
STAT
ON/OFF
END
ON/OFF
FLT
ON/OFF
DISINF
nn
Curr % Level
EMTYCAL
Calibrate – Empty
FULLCAL
Calibrate – Full
EXIT
EXIT
DATE
CURRENT
ddmmmyy
Displays curr Date Only
DAY
dd(Increment 1..31)
MONTH
mm(Increment 1..12)
YEAR
yy(Increment 2010..)
SAVE