background image

 

Serial Number: 

Supplied to: 

Date Installed: 

Installed by: 

It is important that the name from whom you purchased your device and the name of the installer are recorded above.  The installer is responsible for the correct 
installation, start up and demonstrating the operation of this device.  They are also responsible for issuing relevant certificates of compliance (these may differ from 
state to state). 
 

Issue 18 

Jun-23

 

Head Office and Customer Service 

ABN 95 001 717 791 

9-11 McKay Avenue 
PO Box 373 
Leeton  NSW  2705 

Phone: +61 2 6953 7677 
Email:  [email protected] 

Fluid Warming Cabinet 

Single Models: 

F105BT; F420FS; F420C; F210FS; F210C; F210WB; F210S; F260FS; F260C; F260WB; F260S 

Combination Models: 

FF105FS; FB105FS; FS105FS; FF210FS; FB210FS; FS210FS; FF210C; FB210C; FS210C 

FF260FS; FB260FS; FS260FS; FF260C; FB260C; FS260C 

 

 

 

Operation, Maintenance and Installation 

Manual 

Note:  Due to Malmet’s Policy of continuous product improvement; 

 

design and technical specifications are subject to change without notice. 

 

Summary of Contents for F105BT

Page 1: ...state Issue 18 Jun 23 Head Office and Customer Service ABN 95 001 717 791 9 11 McKay Avenue PO Box 373 Leeton NSW 2705 Phone 61 2 6953 7677 Email info malmet com au Fluid Warming Cabinet Single Model...

Page 2: ...rs 4 1 1 Device Operation 5 1 2 Control Display Features 5 1 3 Operating Features 5 1 4 Changing the set temperature lock out feature 6 1 5 Temperature Cut Out 6 1 6 Temperature Sensor Plate 6 2 0 Ins...

Page 3: ...wever owing to Malmet Australia s policy of continuous improvement changes to these specifications may be made at any time without notice on the part of Malmet Australia Pty Ltd Certifications and Com...

Page 4: ...be replaced by a special cord or assembly from the manufacturer or its service agent Do not overload shelves Do not obstruct hot air outlet above top shelf Castors where fitted are for convenience bu...

Page 5: ...able 15 litres per shelf maximum load Single 420 Litre Fluid Warming Cabinets Models F420FS and F420C are designed to hold a maximum of 105 litres of fluid in 1 and 2 litre bottles and bags 420 litre...

Page 6: ...age circuit breaker for approximately three hours This will allow any moisture in the heater to dry out The device can then be connected to an earth leakage circuit breaker protected circuit if requir...

Page 7: ...c cut out fails a secondary safety bi metallic cut out temperature switch will switch off the power to the elements Fig 1 1 6 Temperature Sensor Plate When new product is introduced into the cabinet t...

Page 8: ...Combination Conversion Kit This comprises a Floor Bench Skirt and a Rear Joining Bracket Conversion will take approximately fifteen minutes and requires a screwdriver only Carefully place the bottom w...

Page 9: ...s wikimedia org w index php curid 55610678 Handling Weights of Device Net 47 195 kg Shipping 57 210 kg Shipping with crating 84 275 kg Handling of the device to installation site must be with fork lif...

Page 10: ...ration Maintenance and Installation Manual Issue 18 Page 9 Jun 23 2 1 Service Connections Electrical Connection 240 Volt 10 Amp Plug into 10 Amp G P O 2 2 Device Dimension and Clearances F105BT Fluid...

Page 11: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 10 Jun 23 F210FS Fluid Warming Cabinet Freestanding with Floor Skirt...

Page 12: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 11 Jun 23 F260FS Fluid Warming Cabinet Freestanding with Floor Skirt...

Page 13: ...not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge Children should be supervised to ensure they do not play wit...

Page 14: ...her authorised personnel 1 Check electrical connections as per AS NZS 3551 2012 2 Perform temperature calibration Insert calibrated thermometer Allow cabinet temperature to stabilise Compare cabinet d...

Page 15: ...r Service Display turns on Runs for approximately 1 hour then turns off Fan failure Switch off power supply at main and Call for Service Display is on but unit not heating Element failure Relay board...

Page 16: ...Phase Hz 1 ph 50Hz Amps 2 8 Amps Watts 0 6 kW Environment operating conditions Temperature Relative Humidity 10 C to 25 C 30 to 70 Electrical Connection IEC right angle Power Cord with 3 Pin Plug 10 A...

Page 17: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual Issue 18 Page 16 Jun 23 4 2 Wiring Diagram...

Page 18: ...for issuing the relevant certificates of compliance these may differ from state to state CONDITIONS AND EXCLUSIONS Device must be installed and commissioned according to Malmet s instructions outline...

Page 19: ...ther way from the purchaser to any other person To the extent permitted by law unauthorised use of any parts that were not supplied or approved for use in the applicable device by Malmet will result i...

Page 20: ...component under this warranty Please complete details below Date Purchased Warranty Expiry Date Sold To For Service Contact PROOF OF PURCHASE Please retain your proof of purchase receipt invoice or c...

Page 21: ...Fluid Warming Cabinet Operation Maintenance and Installation Manual DCN 2970 P N 8 M00 84 900 Manufactured by Malmet Australia Pty Ltd ABN 95 001 717 791 www malmet com au...