To rotate anti- clockwise 180° of detector head for wall mount ( See Fig. 16).
180
O
OPERATION AND FUNCTION
Knob setting
The default setting of each knob before ex-factory is as following: Meter:" + ", Time:" Test ", Lux:
, LED mode:" Watch " (See Fig. 17).
Meter knob setting
1. Set Meter knob value at the position of “ - “ for the “ smallest field of view “.
2. Set Meter knob value at the position of “ + “ for the “ largest field of view “.
3. Set Meter knob value at the position between “ - “and “ + “ for “ desired field of view “.
Warning
OFF
Watch
Test
1S.
Rotate slightly
Meter
Time
Lux
LED Mode
Time knob setting
1. Set Time knob value at the position of “ Test “, start to walk test , the load and LED turn on
2 sec then turn off while detector is triggered.
2. Set Time knob value at the position of “ - “, the minimum delay time will be 6 sec.
3. Set Time knob value at the position of “ + “, the maximum delay time will be 10 min.
4. Set Time knob value at the position of “
“, staircase time switch will receive 1 sec signal
once 99 190 31 is triggered, then the light ON 1sec, OFF 9 sec.
5. To adjust the Time knob in between” - “ &” + “ according to user’s desire.