TECHNICAL SPECIFICATIONS
Rated voltage
220-240V~ 50Hz
Load
Max. 8A (cos =1)
Incandescent Lamp: Max. 1840W
230VAC Halogen Lamp: Max. 1000W
12VAC Halogen Lamp: Max. 300VA
Fluorescent Lamp: Max. 400VA
LED Lamp: 150W
Installation height
2.0 - 3.0 m, recommended installation height is approx. 2.5
m. Max 10 m.
Detection angle
up to 270°
LUX
Adjustable from” “ (approx. 5 Lux) to “
“ (
∞
)
TIME
Adjustable from “ - “ (approx. 6 sec) to “ + “
(approx. 10 min) and Test,
LED Mode
OFF / Warning / Watch
Operating temperature range
-20°C – +45°C
Power Consumption
Approx. 1W
IP rating
IP44
Installation and assembly of electrical equipment must be carried out by qualified
electricians. Contact a qualified electrician in the event of fault or break down.
PRODUCT DESCRIPTION
Features
•
Advanced 4 LEDs play an important role in OFF / Warning / Watch function, which enables the
detector to guarantee complete surveillance or warning respectively.
•
Free installation for ceiling or wall mount, and also can be used for corner, recess installation with
wall bracket.
•
Unique designed for multi- direction sensing field rotatable detector head for up / down / forward
/ sideward adjustments.
•
Selectable 3 versions of different detection angles for various purposes.
PACKAGE CONTENTS
Pattern
Rubbe r
washe r
Item
99 190 31
Screw
Ø 3.5 x 10 mm
Wood screws
Ø 4x25.4 mm +
Rubber washers
99 190 35
Wall bracket
Lens shields
Manual
Quantity
1
2
2
1
3
1