GENERAL INFORMATION

This appliance has been tested in accordance with National Safety Standards

 for installation and operation as described in this manual.

Please read all the instructions before beginning your installation.  Check with your local building

code agency  to ensure compliance with local codes.  In the absence of local codes the installation

must comply with National Fuel Gas Code ANSI Z22.3.1. In Canada, current CAN/CGA-B149.1 and

B149.2 installation codes.

Installation and repair should be done by a qualified service person.  The appliance should
be inspected before use and at least annually by a qualified service person.  More frequent
cleaning may be required due to excessive lint from carpeting, bedding material, etc.  It
is imperative that control compartments, burners and circulating air passageways of the
appliance  must  kept  clean.

Page - 2

Unpack all parts from cartons carefully inspecting all parts.  If any parts are damaged or missing,
contact shipper or dealer immediately.

Do not install this appliance using damaged parts.

GAS SUPPLY

For use with natural gas or propane gas, depending on which option you have ordered.  The minimum

inlet gas supply pressure for the purpose of input adjustment:

Natural = Minimum  5.5" Water Column (1.4 kPa)

Maximum 10.5" Water Column (2.6 kPa)

Propane = Minimum 11" Water Column (2.75 kPa)

Maximum 13" Water Column (3.25 kPa)

a. The supply system should include a manual shut-off valve and union in the line, so that the heater

can be disconnected for servicing.

b. The appliance and its individual shut-off valve must be disconnected from the gas supply piping

system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

c. The appliance must be isolated from the gas supply piping system by closing its individual manual

shut-off valve during any pressure testing of the gas supply piping system at test pressures equal

to or less than 1/2 psig (3.5 kPa).

d. A 1/8 inch N.P.T. plugged tapping is provided, for test gauge connection, on the elbow adjacent

to the gas control valve.

Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.

Summary of Contents for ZIRCON 34

Page 1: ... gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vi cinity of this or any other appliance WARNING Improper installation adjustment alteration service or mainte nance can cause injury or property damage Refer to this m...

Page 2: ...ler immediately Do not install this appliance using damaged parts GAS SUPPLY For use with natural gas or propane gas depending on which option you have ordered The minimum inlet gas supply pressure for the purpose of input adjustment Natural Minimum 5 5 Water Column 1 4 kPa Maximum 10 5 Water Column 2 6 kPa Propane Minimum 11 Water Column 2 75 kPa Maximum 13 Water Column 3 25 kPa a The supply syst...

Page 3: ...appliances equipped with a draft hood The damper saves energy by preventing the escape of heated air through the venting system when the appliance is not in use It has four quadrants of bimetal which remain closed when the appliance is not in operation Upon ignition of the appliance the hot flue gases reach the damper causing the quadrants to flex thereby opening the vent passage within a short pe...

Page 4: ...arances around the opening There must be adequate accessibility clearance for servicing and proper operation Page 4 CAUTION Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Clothing or other flammable material should not be placed on or near the appliance Figure 1 Figure 2 CLEARANCES SIDEWALL AND BACKWALL INSTALLATION Unit to Sidewall ...

Page 5: ...ING REQUIREMENTS Use a B vent masonry or class A chimney Follow all manufacturers requirements and local building codes If you are using B vent utilize the support box supplied with unit GAS LINE ATTACHMENT The gas supply line must be installed at the rear right side of the gas unit This supply line must be a minimum of 1 2 black iron type pipe A separate manual shut off valve should always be use...

Page 6: ...ort box The cleat will lock into place as the pipe is pushed up into the support box 2 Slip one of the mid sections over the slip connector Slide the mid section up only enough to allow the placement of the next section of pipe between the unit and the bottom of the mid pipe that was placed onto the slip connector 3 Place the remaining mid section into the collar on top of the unit 4 Pull the mid ...

Page 7: ...en under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in the control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly D...

Page 8: ...e flow of combustion air is not obstructed 4 If you are unsure how to perform these maintenance procedures have a qualified field service person check the unit at least annually NOTE During the first few fires the odor of paint or oils remaining from manufacturing are likely to release an odor This is normal and will stop as soon as the paint has cured 5 If for any reason a log should break it mus...

Page 9: ...ot AssemblySit 0145003 11 MV 11 Piezo Lighter Electrode 12 MV 12 Pilot Hood 13 MV 13 Thermocouple Sit 0290136 6 13 12 11 10 9 8 7 5 3 2 1 The pilot flame adjustment is located behind the valve cover Remove the cover screw and cover Locate the pilot adjustment at the upper right hand of the valve The pressure regulator adjustment is located on the bottom of the valve CAUTION Only trained and qualif...

Page 10: ...x 13 PilotFlame Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 800 535 8955 Fax 707 571 8036 email info malmfireplaces com Minimum 1 4 opening Logs have notches for proper placement on grate ...

Reviews: