__________________________________________________________________________________
5
1. Unscrew the top part of the filter pressure
container (6 screws).
2. Remove the contaminated filter, wipe the inside
of the container.
3. Check the condition of the rubber seal in the top
cover. If the seal is damaged, replace it.
4. Install a new filter on the container cover and
screw it back.
5. Check the container for leakage. If the container
is not absolutely tight, tighten all screws that
fasten the top cover.
7. Possible Faults
Fault
Probable cause
Recommendation
The unit does not work at all.
Compressed air supply failure. Hose
damage.
Check the compressed air source.
Check that connecting hoses are not
damaged.
The unit does not supply the sufficient
amount of air.
Air hose or air channel blocked.
Air escapes through leakages.
The baffle is clogged.
The filter in CA Conditioner is clogged.
Check and remove the possible obstacle.
Check
all
sealing
elements
and
connections, check that the hose is not
damaged and without leaks.
Replace the baffle in CA Pressure .
Replace the filter.
8. Storage
If any fault, sudden decrease or increase in air
supply occurs and the user is at a contaminated
workplace, it is necessary to leave the workplace
and to check the following:
That the unit is assembled correctly.
The filter condition in CAP Conditioner.
That the air hose is not damaged. It is
necessary to make sure that, during work,
the hose is not got caught at projecting
objects and a crack cannot occur.
That the noise damper in CA Pressure is
not clogged.
That the seal on the safety hood is in good
condition.
All components of CleanAIR systems must be
stored in rooms with temperatures between 0°C and
40°C with relative air humidity between 20% and
80% Rh. The storage time in closed containers is
max. 2 years, except for the batteries!.
9. Warranty
Warranty for manufacturing defects is 12 months
from the date of sale to the customer. A claim must
be filed with the sales organization and the proof of
sale (invoice or delivery note) must be submitted.
Warranty can be admitted only if no interventions
were made in the filter-ventilation unit and the
charger.
Warranty does not cover, in particular, defects
caused by a late replacement of the filter or by
using a filter damaged by cleaning and blowing.
10. Technical Data
Notified body for CE testing:
Výzkumný ústav bezpečnosti práce, v.v.i. – ZL
Testing Laboratory No. 1024
Jeruzalémská 9, 116 52 Praha 1
Authorized Body 235
Notified Body 1024
CA Pressure
Pressure
Pressure FC
Pressure for mask
Minimum air flow
170 l/min
-1
170 l/min
-1
160 l/min
-1
Maximum air flow
>400 l/min
-1
>400 l/min
-1
>400 l/min
-1
Weight of unit
200 g
250 g
380 g
Inlet connection
Compatible with RECTUS series 25,26 and CEYN320
Outlet connection
CA-40
MINI DN 5
Noise level of unit
61 dB
61 dB
61 dB
Belt size
60-150 cm
60-150 cm
60-150 cm
Supply pressure range
300 – 1000 kPa
300 – 1000 kPa
300 – 1000 kPa
Recommended temperature range at
work
+10 to +60°C
+10 to +60°C
+10 to +60°C