background image

 

1

98-0060-0187-3/2 

8511CN Respirator P95  

User Instructions Insert 

Activity Summary 

 

Initials 

Date 

Comments 

LA 

8/2011 

Initial submission   

EJ

 

3/2020

 

Update GB2626 to 2019.  Add clarification re: sandblasting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 8511CN

Page 1: ...1 98 0060 0187 3 2 8511CN Respirator P95 User Instructions Insert Activity Summary Initials Date Comments LA 8 2011 Initial submission EJ 3 2020 Update GB2626 to 2019 Add clarification re sandblasting ...

Page 2: ...eference 98 0060 0187 3 2 This respirator has dual approval as a United States US National Institute for Occupational Safety and Health NIOSH N95 particulate respirator and as a China GB2626 2019 KN95 particulate respirator Specific information is provided where applicable GB2626 2019 KN95 ...

Page 3: ...ction industry or 4 4 methylene dianiline MDA specify other types of respiratory protection This respirator does not supply oxygen Biological Particles This respirator can help reduce inhalation exposures to certain airborne biological particles e g mold Bacillus anthracis Mycobacterium tuberculosis etc but cannot eliminate the risk of contracting infection illness or disease OSHA and other govern...

Page 4: ...10 times the permissible exposure limit PEL or according to specific OSHA standards or applicable government regulations whichever is lower 3 Do not alter wash abuse or misuse this respirator 4 Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator 5 Respirators can help protect your lungs against certain ...

Page 5: ...conduct a user seal check before use as specified in User Instructions If you cannot achieve a proper seal do not enter the contaminated area See your supervisor Time Use Limitation If respirator becomes damaged soiled or breathing becomes difficult leave the contaminated area immediately and replace the respirator Fitting Instructions Must be followed each time respirator is worn 4o F 20o C 86o F...

Page 6: ...inward while moving your fingertips down both sides of the nosepiece Fig 3 Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance Use two hands 4 Perform a User Seal Check prior to each wearing To check the respirator to face seal place both hands completely over the respirator and inhale sharply Fig 4 Be careful not to disturb the position of th...

Page 7: ... and cup respirator in hand to maintain position on face Pull bottom strap over head Still holding respirator in position pull top strap over head and remove respirator This respirator contains no components made from natural rubber latex ...

Page 8: ...do not contain oil FOR MORE INFORMATION In China contact Website www 3M com cn PPE Tel 86 21 22105335 3M 2020 All rights reserved 3M is a trademark of 3M Company For Use in China GB2626 2019 approved KN95 At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil ...

Page 9: ...9 3M China Co Ltd 222 TianLin Road Shanghai China 200233 Tel 021 2210 5335 Fax 021 2210 5035 3M PSD products are for occupational use only ...