Malema M-200 Operating Instructions And Quick Start Manual Download Page 5

malema.com

Specifications

04

Construction Materials

Reed Switch Replacement

For reed Switch replacement

1.  Loosen allen set screws (4-40) on face of body.

2.  Remove and replace reed switch if needed.

3.  

Normally Open

     Move switch downward until switch closes then move upward until switch opens. Very gently retighten allen screws.

     

Normally Closed

     Move switch downward until it closes then move upward very slightly maintaining a closed contact. Very gently retighten

     allen screws.

4.  If possible cycle unit on and off to test. if unit is not installed, turning upside down will simulate the flow.

Housing

Acrylic

Aluminium

Brass

316SS

PTFE

Piston

316SS

PTFE

Orifice Plate or disc

316SS

PTFE

Spring

316SS

N/A

Retaining Ring

Stainless Steel (PH 15-7 MO, AMS 5520, AISI-632)

 (Passivated)

PTFE

Pressure and Temperature

Specifications

Maximum Operating (psig)

Burst (psig)

Maximum Operating Temperature

200

400

77°C (170°F)

1,000

3,000

149°C (300°F)

1,500

3,000

149 C (300

o

F)

3,000

5,000

149 C 

(300

o

F)

80

160

104 C (220

o

F)

Flow calibration

Set point Accuracy

Set point Differential( Deadband )

Repeatability

( Higher accuracy units available )

10% maximum

15%

± 2 maximum

Reed Switch Data 

(Electrical Ratings)

Reed Switch

Switching Voltage

Breakdown Voltage

DC Resistive

AC Resistive

Switching Current

10 Watts SPST or 3 Watts SPDT (Hermetically Sealed)

UL Recognized. File E47258

Operating temperature -40°C to 125°C

200 VDC ( 170 VDC for SPDT )

250 VDC ( 200 VDC for SPDT )

10 VA (3 VA for SPDT )

10 Watts (3 Watts for SPDT )

0.5 A ( 0.25 A for SPDT )

1.2 A ( 0.5 A for SPDT )

Lead Wires

No 24 to 18 AWG. 18” length, Polymeric UL Recognized

( Belden cable or special shielded cable is available )

Lead Wires Color

SPST: 2 blue wires

SPDT: Green - Common, Yellow - Normally Closed,

Orange - Normally Open

Summary of Contents for M-200

Page 1: ...malema com M 200 High flow adjustable flow switch with right angle Flow Operating Instructions and Quick Start Guide ...

Page 2: ...of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Construction 03 Specification 04 Certification 05 Dimensional drawings 05 Flow Setting 07 Ordering Information 08 Warranty 08 ...

Page 3: ... be mounted in any orientation Adequate filtration and sealing procedures should be used when mounting in flow lines Operating Environment Choose a location with an ambient temperature of 10 35 C and relative humidity value 80 RH without exposure to direct sunlight Avoid environments with high electromagnetic noise or vibration Make sure that the module is protected from cor rosive liquid or water...

Page 4: ... C Normally closed 1 Loosen allen set screws 4 40 on face of body These are the set screws holding the reed switch in place 2 Move the reed switch downwards until it shows a closed contact on the multi meter 3 Tighten 4 40 allen set screws on face of the body 4 Cycle until on and off by turning upside down to simulate flow This may necessitate some refinement of the exact location of the reed swit...

Page 5: ...ssivated PTFE Pressure and Temperature Specifications Maximum Operating psig Burst psig Maximum Operating Temperature 200 400 77 C 170 F 1 000 3 000 149 C 300 F 1 500 3 000 149 C 300o F 3 000 5 000 149 C 300o F 80 160 104 C 220o F Flow calibration Set point Accuracy Set point Differential Deadband Repeatability Higher accuracy units available 10 maximum 15 2 maximum Reed Switch Data Electrical Rat...

Page 6: ...d REACH can be obtained from Malema on request Certifications Dimensional and Cut Away drawings Illustrated is the M 200 model with 3 8 ports Housing A B Acrylic 1 25 0 625 Aluminum 1 0 500 Brass 1 0 500 316SS 1 0 500 PTFE 1 25 0 625 05 CONTACT ARRANGEMENT Electrical Color Coding SPST 2 Blue Wires SPDT Orange Normally Open Yellow Normally Closed Green Common ...

Page 7: ...ated is the M 200 model with 3 4 ports Illustrated is the M 200 Model with SAE8 ports Note The M 200 Model with 3 4 ports is only available in Brass PTFE and 316SS 06 Note The M 200 Model with SAE8 ports is only available in Brass and 316 Stainless Steel ...

Page 8: ...ll returns of equipment must go to the following address Malema Sensors 1060 S Rogers Circle Boca Raton FL 33487 USA Warranty Note The flow switch performance will be affected in the vicinity of Magnets Electromagnets and Ferrous metals Hence adequate protection should be provided while installing in close proximity to such interferences or relocate the flow switch away from them appropriately Ord...

Reviews: