![Malber TD6003 Service Manual Download Page 77](http://html.mh-extra.com/html/malber/td6003/td6003_service-manual_697716077.webp)
09.A
13-05-03
A520
}
B051
B540
B670
B550
B530 (n°4)
A490 (n°2)
A500
B020
B560
B030 B006
Step 14
Removing and/or replacing heater element (B560) and air inspection cover (B051):
(a)
From the back of the drier, use a crosshead screwdriver to remove the four fixing screws (
B530
)
securing the heater element mounting cover (
B550
).
(b)
Remove the two fixing screws (
A490
) securing the heater element (
B560
).
(c)
Remove the fixing screw (
A520
) securing the air intake cover assembly (
B051
).
(d)
Disconnect the heater element terminal block at the bottom of the drier, then remove the heater
element (
B560
).
To replace the heater element:
Disconnect the contacts of the thermostats (
B006
)(
B030
), noting their positions and recover:
- the maximum temperature thermostat (
B006
)
- the manual reset safety thermostat (
B030
)
- the thermostat plate (
B020
)
- the 2 thermostat plate fixing screws (
A500
)
(e)
To re-assemble, follow the same procedure in reverse order.
Step 15B
For driers produced from week 18 of 2003
(from serial number 200318...)
Technical Information
code
466000021
Removing and/or replacing:
- the manual reset safety thermostat (B006)
- the automatic reset maximum temperature thermostat (B030)
(a)
Remove the heater element mounting cover (
B550
) (
Step 14
)
(b)
In order to have better access to the heater element terminal block, it is advisable
to remove the air intake inspection cover (
B051
) (
Step 14
) and disconnect it.
(c)
Remove the 2 screws (
A500
) anchoring the thermostat mounting plate (
B020
)
and replace.
(d)
To re-assemble, follow the same procedure in reverse order.
Step 15A
For driers produced prior to week 18 of 2003
Removing and/or replacing:
- the manual reset safety thermostat (B006)
- the automatic reset maximum temperature thermostat (B030)
(a)
Remove the top cover (
B360
) as described in
Step 1
.
(b)
To improve access, it is advisable to remove the rear panel (
B580
) following
Step 16
, dismantling
only those parts necessary.
(c)
Remove the cover (
B550
) together with the heater element (
B560
) following
Step 14
, making sure
that the electric wiring is disconnected.
(d)
Remove the two fixing screws (
A500
) securing the galvanised plate (
B020
), then remove the
thermostat to be replaced.
(e)
To re-assemble, follow the same procedure in reverse order.
MAINTENANCE PROCEDURES
B020
A500
B030 B006