background image

3 ENGLISH

NOTE:

 The declared noise emission value(s) has 

been measured in accordance with a standard test 

method and may be used for comparing one tool with 

another.

NOTE:

 The declared noise emission value(s) 

may also be used in a preliminary assessment of 

exposure.

WARNING:

 

Wear ear protection.

WARNING:

 

The noise emission during actual 

use of the power tool can differ from the declared 

value(s) depending on the ways in which the 

tool is used especially what kind of workpiece is 

processed.

WARNING:

 

Be sure to identify safety mea-

sures to protect the operator that are based on an 

estimation of exposure in the actual conditions of 

use (taking account of all parts of the operating 

cycle such as the times when the tool is switched 

off and when it is running idle in addition to the 

trigger time).

Vibration

The vibration total value (tri-axial vector sum) deter-

mined according to EN62841-1:

Model UB100D

Work mode: operation without load

Vibration emission (a

h

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

The vibration total value (tri-axial vector sum) deter-

mined according to EN50636-2-100:

Model UB101D

Work mode: operation without load

Vibration emission (a

h

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

NOTE:

 The declared vibration total value(s) has been 

measured in accordance with a standard test method 

and may be used for comparing one tool with another.

NOTE:

 The declared vibration total value(s) may also 

be used in a preliminary assessment of exposure.

WARNING:

 

The vibration emission during 

actual use of the power tool can differ from the 

declared value(s) depending on the ways in which 

the tool is used especially what kind of workpiece 

is processed.

WARNING:

 

Be sure to identify safety mea-

sures to protect the operator that are based on an 

estimation of exposure in the actual conditions of 

use (taking account of all parts of the operating 

cycle such as the times when the tool is switched 

off and when it is running idle in addition to the 

trigger time).

EC Declaration of Conformity

For European countries only

The EC declaration of conformity is included as Annex A 

to this instruction manual.

SAFETY WARNINGS

General power tool safety warnings

WARNING:

 

Read all safety warnings, instruc-

tions, illustrations and specifications provided 

with this power tool.

 Failure to follow all instructions 

listed below may result in electric shock, fire and/or 

serious injury.

Save all warnings and instruc-

tions for future reference.

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-operated 

(cordless) power tool.

Work area safety

1. 

Keep work area clean and well lit.

 Cluttered or 

dark areas invite accidents.

2. 

Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust.

 Power tools create sparks 

which may ignite the dust or fumes.

3. 

Keep children and bystanders away while 

operating a power tool.

 Distractions can cause 

you to lose control.

Electrical safety

1. 

Power tool plugs must match the outlet. Never modify 

the plug in any way. Do not use any adapter plugs 

with earthed (grounded) power tools. 

Unmodified plugs 

and matching outlets will reduce risk of electric shock.

2. 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators.

 There is an increased risk of elec-

tric shock if your body is earthed or grounded.

3. 

Do not expose power tools to rain or wet con-

ditions.

 Water entering a power tool will increase 

the risk of electric shock.

4. 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges 

or moving parts.

 Damaged or entangled cords 

increase the risk of electric shock.

5. 

When operating a power tool outdoors, use an 

extension cord suitable for outdoor use.

 Use of a cord 

suitable for outdoor use reduces the risk of electric shock.

6. 

If operating a power tool in a damp location 

is unavoidable, use a residual current device 

(RCD) protected supply.

 Use of an RCD reduces 

the risk of electric shock.

7. 

Power tools can produce electromagnetic fields 

(EMF) that are not harmful to the user.

 However, 

users of pacemakers and other similar medical 

devices should contact the maker of their device and/

or doctor for advice before operating this power tool.

Personal safety

1. 

Stay alert, watch what you are doing and use 

common sense when operating a power tool. 

Do not use a power tool while you are tired or 

under the influence of drugs, alcohol or med

-

ication.

 A moment of inattention while operating 

power tools may result in serious personal injury.

Summary of Contents for UB101D

Page 1: ...INSTRUCTION MANUAL Cordless Blower UB100D UB101D ENGLISH Original instructions Read before use ...

Page 2: ... above Use of any other battery cartridges and chargers may cause injury and or fire Symbols The followings show the symbols which may be used for the equipment Be sure that you understand their meaning before use Take particular care and attention Read instruction manual Keep hands away from rotating parts Long hair may cause entanglement accident Keep bystanders away Wear eye and ear protection ...

Page 3: ...warnings instruc tions illustrations and specifications provided with this power tool Failure to follow all instructions listed below may result in electric shock fire and or serious injury Save all warnings and instruc tions for future reference The term power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool Work area safety 1 Keep work ...

Page 4: ...ower tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users 5 Maintain power tools and accessories Check for misalignment or binding of moving parts break age of parts and any other condition that may affect the power tool s operation If damaged have the pow...

Page 5: ...ng the machine always wear non slip and protective footwear Non skid closed toed safety boots and shoes will reduce the risk of injury 6 Use personal protective equipment Always wear eye protection Protective equipment such as a dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Operation 1 Switch off the machine and remove ...

Page 6: ... injury 6 Do not expose a battery pack or tool to fire or excessive temperature Exposure to fire or tem perature above 130 C may cause explosion 7 Follow all charging instructions and do not charge the battery pack or tool outside the temperature range specified in the instruc tions Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of f...

Page 7: ...o the han dling of hot battery cartridges 15 Do not touch the terminal of the tool imme diately after use as it may get hot enough to cause burns 16 Do not allow chips dust or soil stuck into the terminals holes and grooves of the battery cartridge It may result in poor performance or breakdown of the tool or battery cartridge 17 Unless the tool supports the use near high voltage electrical power ...

Page 8: ...r wiper nozzle perform the installation procedure in reverse Installing or removing the long nozzle Optional accessory for UB100D UB101D Install the long nozzle in the same way as the nozzle To remove the long nozzle perform the installation proce dure in reverse Installing or removing the tapered nozzle Optional accessory for UB100D UB101D Attach the tapered nozzle to the nozzle and then install ...

Page 9: ...ing or removing of the battery cartridge CAUTION Hold the machine and the battery cartridge firmly when installing or removing bat tery cartridge Failure to hold the machine and the battery cartridge firmly may cause them to slip off your hands and result in damage to the machine and battery cartridge and a personal injury CAUTION Always install the battery cartridge fully until the red indicator ...

Page 10: ...ttery cartridge to indi cate the remaining battery capacity The indicator lamps light up for a few seconds Indicator lamps Remaining capacity Lighted Off 75 to 100 50 to 75 25 to 50 0 to 25 NOTE Depending on the conditions of use and the ambient temperature the indication may differ slightly from the actual capacity Switch action WARNING Before installing the battery car tridge into the machine al...

Page 11: ...ion in a corner start from the corner and then move to wide area For UB100D For UB101D Vacuuming operation CAUTION When performing the vacuuming operation be sure to attach the dust bag and nozzle in place to the machine CAUTION Check the dust bag frequently for wear or deterioration CAUTION Be sure to fasten the fastener of the dust bag before operating the machine CAUTION Always switch off the m...

Page 12: ...f and the battery cartridge is removed before attempting to perform inspection or maintenance To maintain product SAFETY and RELIABILITY repairs any other maintenance or adjustment should be performed by Makita Authorized or Factory Service Centers always using Makita replacement parts Cleaning the machine Clean the machine by wiping off dust with a dry cloth or one dipped in soapy water and wrung...

Page 13: ...ng Recharge the battery If recharging is not effective replace battery The drive system does not work correctly Ask your local authorized service center for repair Abnormal vibration stop the machine immediately The drive system does not work correctly Ask your local authorized service center for repair Motor cannot stop Remove the battery immediately Electric or electronic malfunction Remove the ...

Page 14: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885818 224 EN 20200609 ...