background image

5

The air stream may contain carbon monoxide or other 
vapors, or particles from the tank or other components.

• Sprayed materials such as paint, paint solvents, paint 

remover, insecticides, weed killers, etc., contain 
harmful vapors and poisons.

• Breathing compressor or sprayed materials vapor can 

result in serious injury.

HOW TO PREVENT IT

• Never inhale air from the compressor, either directly or 

from a breathing device connected to the compressor. 
Work in an area equipped with good cross ventilation.

• Read and follow the safety instructions provided on the 

label or safety data sheet for the material you are 
spraying.
Use an approved respirator designed for use with your 
specific application.

WARNING: Risk from noise

Wear hearing protection to protect your ears against 
exhaust noise and noise during operation.

WARNING

Risk from Compressed Air
WHAT CAN HAPPEN

The compressed air stream can cause soft tissue 
damage, and can propel dirt, chips, loose particles and 
small objects at high speed, resulting in property damage 
or personal injury.

HOW TO PREVENT IT

• Always wear approved safety glasses with side shields 

when using or maintaining the compressor.

• Never point any nozzle or sprayer toward any part of 

the body or at other people or animals.

• Always turn the compressor off and bleed pressure 

from the air line before attempting maintenance, 
attaching tools or accessories.

WARNING

Risk from Moving Parts
WHAT CAN HAPPEN

The compressor cycles automatically when the pressure 
switch is in the on/auto position. If you attempt repair or 
maintenance while the compressor is operating or 
plugged in, you can expose yourself to moving parts. 
These moving parts can cause serious injury.

HOW TO PREVENT IT

• Always unplug the compressor and release air 

pressure from the tank and any attachments before 
attempting any maintenance or repair. 

• Never operate the compressor with guards or covers 

which are damaged or removed. 

• Keep your hair, clothing, and gloves away from moving 

parts. Loose clothes, jewelry, or long hair can be 
caught in moving parts. 

• Air vents may cover moving parts and should be 

avoided as well.

WARNING

Risk of Burn
WHAT CAN HAPPEN

Contact with hot parts such as the compressor head or 
outlet tubes could result in a serious skin burn.

HOW TO PREVENT IT

• Never touch hot components during or immediately 

after operation of the compressor. Do not reach around 
protective shrouds or attempt maintenance until unit 
has been allowed to cool.

GLOSSARY

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure 
of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure 
of pressure.

CUT-IN PRESSURE: While the motor is off, air tank 
pressure drops as you continue to use your accessory or 
air tool. When the tank pressure drops to a certain level 
the motor will restart automatically re-started is called 
“cut-in pressure”.

CUT-OUT PRESSURE: When you turn on your air 
compressor, it begins to run, air pressure in the air tank 
begins to build. It builds to a certain pressure before the 
motor automatically shuts off - protecting your air tank 
from pressure higher than its design rating. The pressure 
at which the motor shuts off is called “cut-out pressure”.

DUTY CYCLE

All Makita manufactured air compressors are 
recommended to be operated on not more than a 50% 
duty cycle. This means an air compressor that pumps air 
more than 50% in one hour is considered misuse because 
the air compressor is undersized for the required air 
demand.

GENERAL INFORMATION

This air compressor is equipped with an Oil-Less pump 
designed for durability and no maintenance.

The compressor can be used for properly rated pneumatic 
nailers and staplers.  An air pressure regulator is supplied 
for these applications.

WARNING

Never use compressor for applications other than to 
operate a properly rated nailer or stapler.  Use of the 
compressor for other applications could result in property 
damage and personal injury.

Separate air transformers which combine the functions of 
air regulation and/or moisture and dirt removal should be 
used where applicable.

ON-RECEIPT INSPECTION

DAMAGE: Each air compressor outfit is carefully tested 
and checked before shipment. With improper handling, 
damage may result in transit and cause problems with 
compressor operation.

Summary of Contents for MAC100Q

Page 1: ...Air Compressor Instruction Manual Compresseur d air Manuel d instructions Compresor de aire Manual de instrucciones MAC100Q MAC210Q MAC320Q ...

Page 2: ...ssure gauge 7 Outlet pressure gauge 8 Quick coupler 9 Air tank 10 Drain valve 11 Pressure switch 12 Power cord 13 ON AUTO OFF switch 14 Pressure switch unloading valve Note The shape of the drain valve differs between MAC100Q and MAC210Q 2 1 3 6 5 7 8 9 10 11 13 12 14 4 MAC100Q MAC210Q 2 1 3 6 5 7 9 10 11 13 12 14 8 4 MAC320Q ...

Page 3: ...L instructions carefully before operating www makitatools com www makita ca Model MAC100Q MAC210Q MAC320Q MAX Output Power 350 W 800 W 1100 W SCFM 90 PSIG 0 7 2 0 2 6 Cut In Pressure 105 PSIG 0 72 MPa Cut Out Pressure 135 PSIG 0 93 MPa Bore x Stroke x Qty 51 mm x 8 mm x 2 64 mm x 14 mm x 2 64 mm x 17 mm x 2 Voltage Single Phase 120 V AC Hz 60 Hz Motor RPM 1 750 min 1 Lubrication Oil Less Tank Size...

Page 4: ...aximum allowable pressure rating of attachments Never use the compressor to inflate small low pressure objects such as children s toys footballs basketballs etc WARNING Risk of Attachments and Accessories Bursting WHAT CAN HAPPEN Exceeding the pressure rating of air tools spray guns air operated accessories tires AND other inflatables can cause them to explode or fly apart and could result in seri...

Page 5: ...ing parts Air vents may cover moving parts and should be avoided as well WARNING Risk of Burn WHAT CAN HAPPEN Contact with hot parts such as the compressor head or outlet tubes could result in a serious skin burn HOW TO PREVENT IT Never touch hot components during or immediately after operation of the compressor Do not reach around protective shrouds or attempt maintenance until unit has been allo...

Page 6: ...the check valve and into the air tank Useable air is not available until the compressor has raised the air tank pressure above that required at the air outlet CHECK VALVE When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing air pressure to remain inside the air tan...

Page 7: ... event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances The outlet mu...

Page 8: ... or transformers 2 Check for any unusual noise and or vibration 3 Manually check all safety valves to make sure they are operating properly WARNING Risk of bursting Check Safety Valve If safety valve does not operate properly over pressurization of the air tank may result in rupture or explosion causing personal injury and property damage 4 Inspect air filter replace if necessary 5 Inspect air lin...

Page 9: ... 7 Manomètre de sortie 8 Raccord rapide 9 Réservoir d air 10 Robinet de vidange 11 Manostat 12 Cordon d alimentation 13 Interrupteur MARCHE AUTOMATIQUE ARRÊT 14 Valve de décompression de manostat Remarque La forme du robinet de vidange des modèles MAC100Q et MAC210Q n est pas la même 2 1 3 6 5 7 8 9 10 11 13 12 14 4 MAC100Q MAC210Q 2 1 3 6 5 7 9 10 11 13 12 14 8 4 MAC320Q ...

Page 10: ...les recommandations de sécurité et TOUTES les instructions avant d utiliser l appareil www makitatools com www makita ca Modèle MAC100Q MAC210Q MAC320Q Puissance de sortie MAX 350 W 800 W 1 100 W Pi3 min std 90 PSIG 0 7 2 0 2 6 Pression d enclenchement 105 PSIG 0 72 MPa Pression de déclenchement 135 PSIG 0 93 MPa Alésage x Course x Qté 51 mm x 8 mm x 2 64 mm x 14 mm x 2 64 mm x 17 mm x 2 Tension m...

Page 11: ...on Si le réservoir d air présente une fuite le remplacer immédiatement par un nouveau réservoir ou remplacer le compresseur au complet S abstenir de percer un trou dans le réservoir d air de souder ce dernier ou de le modifier de quelque façon que ce soit cela l affaiblirait Le réservoir pourrait se rompre ou exploser Remplacer par un nouveau réservoir d air Suivre les recommandations du fabricant...

Page 12: ...ttes de sécurité homologuées munies d écrans latéraux durant l utilisation ou l entretien du compresseur Ne jamais diriger la buse ou le pulvérisateur vers une partie du corps ou vers une autre personne ou un animal Toujours mettre le compresseur hors tension et évacuer la pression de la canalisation d air avant d effectuer l entretien ou encore de fixer des outils ou des accessoires AVERTISSEMENT...

Page 13: ...ation et réaliser les opérations d entretien nécessaires Bien s assurer de vidanger l eau du réservoir d air 2 Protéger le cordon électrique et le tuyau à air contre les dommages pour éviter qu on y trébuche ou qu on marche dessus Entreposer le compresseur d air dans un endroit propre et sec DESCRIPTION DU FONCTIONNEMENT ROBINET DE VIDANGE Le robinet de vidange est situé au bas du réservoir d air ...

Page 14: ... un réglage inférieur commencer par réduire la valeur à une pression inférieure à celle souhaitée Selon les exigences de chaque accessoire particulier la pression d air réglée à la sortie pourrait devoir être ajustée pendant que l accessoire est en fonction SORTIE D AIR COMPRIMÉ À utiliser avec les outils pneumatiques à pression régulière Pression maximale de la sortie 135 PSIG 0 93 MPa PROCÉDURES...

Page 15: ...fermement le tuyau dans la main lors de son installation ou de son débranchement pour éviter tout coup de fouet Perdre le contrôle du tuyau peut entraîner des blessures et des dommages matériels 1 Avant de raccorder un tuyau à air ou des accessoires s assurer que le levier du manostat est à la position Arrêt OFF et que le régulateur d air ou la soupape d arrêt est fermé 2 Raccorder le tuyau et les...

Page 16: ...ter le filtre à air et le remplacer au besoin 5 Inspecter les conduites d air et les raccords pour s assurer qu il n y a pas de fuite apporter les corrections au besoin Après chaque année d utilisation ou encore si on soupçonne la présence d un problème Vérifier les conditions d entrée de la pompe de compression d air et des soupapes d échappement Vérifier l état du clapet antiretour Le remplacer ...

Page 17: ...e 7 Manómetro de la toma 8 Acople rápido 9 Tanque de aire 10 Válvula de drenado 11 Interruptor de presión 12 Cable eléctrico 13 Interruptor de Encendido Auto Apagado 14 Válvula de descarga del interruptor de presión Nota La forma de la válvula de drenado es diferente entre MAC100Q y MAC210Q 2 1 3 6 5 7 8 9 10 11 13 12 14 4 MAC100Q MAC210Q 2 1 3 6 5 7 9 10 11 13 12 14 8 4 MAC320Q ...

Page 18: ...ad así como TODAS las instrucciones antes de utilizar el equipo www makitatools com www makita ca Modelo MAC100Q MAC210Q MAC320Q Producción máxima de energía 350 W 800 W 1 100 W SCFM 90 PSIG 0 7 2 0 2 6 Presión de activación 105 PSIG 0 72 MPa Presión de desactivación 135 PSIG 0 93 MPa Calibre x Ciclo x Cantidad 51 mm x 8 mm x 2 64 mm x 14 mm x 2 64 mm x 17 mm x 2 Voltaje Monofásico 120 V CA Hz 60 ...

Page 19: ...bilitará El tanque podrá romperse o explotar Cambie el tanque por uno nuevo Siga las recomendaciones del fabricante del equipo y nunca exceda la clasificación de la presión máxima permitida de los aditamentos No use nunca un compresor para inflar objetos de baja presión como juguetes para niños pelotas o balones etc ADVERTENCIA Riesgo de que los aditamentos o accesorios exploten LO QUE PUEDE PASAR...

Page 20: ...ión automática Si va a hacer algún servicio de reparación o mantenimientos mientras el compresor está siendo utilizado o está conectado puede exponerse a las piezas móviles Estas piezas móviles pueden causar graves lesiones CÓMO PUEDE PREVENIR ESTO Desconecte siempre el compresor y libere la presión de aire del tanque y de cualquier aditamento antes de realizar cualquier servicio de mantenimiento ...

Page 21: ...or se apaga automáticamente antes de alcanzar la presión de desactivación normal 1 Apague todas las herramientas 2 Desconecte el compresor o apague el interruptor de presión 3 Espere hasta que el compresor se enfríe Cerca de 10 min 4 Vuelva a conectar el compresor o encienda el interruptor de presión para arrancar el compresor 5 Reanude la operación Si utiliza un cable de extensión el compresor se...

Page 22: ... Sitúe el compresor de aire en un lugar limpio seco y bien ventilado El filtro del aire debe mantenerse sin obstrucciones que podrían reducir el suministro de aire del compresor de aire El compresor de aire deberá situarse al menos 30 centímetros 12 pulgadas de la pared o de cualquier otra obstrucción que interfiera con el flujo de aire La cabeza y cubierta del compresor de aire están diseñadas pa...

Page 23: ...ra de aire o los accesorios asegúrese que la palanca del interruptor de la presión está en la posición de apagado OFF y que la válvula de cierre del regulador de aire está cerrada 2 Coloque la manguera y los accesorios Una presión excesiva de aire implica un peligroso riesgo de explotación Compruebe la clasificación de presión máxima del fabricante para las herramientas y accesorios para equipos d...

Page 24: ...as válvulas de escape del compresor de aire Revise la condición de la válvula de escape y reemplácela si está dañada o gastada 6 Asegúrese de que todos los tornillos pernos y cubiertas estén bien apretados Revise sus condiciones de forma periódica ADVERTENCIA Asegúrese de que todos los tornillos pernos y cubiertas estén bien apretados firmemente Si las placas de tornillos o las cubiertas se suelta...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ...ks that are specially designed to filter out microscopic particles ADVERTENCIA Algunos tipos de polvo creados por el lijado serrado amolado taladrado y otras actividades de la construccion contienen sustancias quimicas reconocidas por el Estado de California como causantes de cancer defectos de nacimiento y otros peligros de reproduccion Algunos ejemplos de estos productos quimicos son plomo de pi...