6
Miter angle
Bevel angle
0°
45° (left and right)
93 mm x 95 mm
93 mm x 67 mm
0°
69 mm x 135 mm
69 mm x 95 mm
53 mm x 95 mm
49 mm x 67 mm
45° (left)
35 mm x 135 mm
35 mm x 94 mm
No load speed (min
-1
)
4,600
Dimensions (L x W x H)
530 mm x 476 mm x 532 mm
Net weight
12.6 kg
Safety class
/II
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END217-3
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・
Read instruction manual.
・
DOUBLE
INSULATION
・
To avoid injury from flying debris, keep
holding the saw head down, after
making cuts, until the blade has come
to a complete stop.
・
Do not place hand or fingers close to
the blade.
・
For your safety, remove the chips, small
pieces, etc. from the table top before
operation.
・
Always set SUB-FENCE to left position
when performing left bevel cuts. Failure
to do so may cause serious injury to
operator.
・
To loosen the bolt, turn it clockwise.
・
Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible
recycling facility.
ENE004-1
Intended use
The tool is intended for accurate straight and miter
cutting in wood. With appropriate saw blades, aluminum
can also be sawed.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
For Model LS1040F
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.34 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
ENG905-1
Noise
The typical A-weighted noise level determined according
to EN61029:
Sound pressure level (L
pA
) : 91 dB(A)
Sound power level (L
WA
) : 101 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN61029:
Vibration emission (a
h
) : 2.5 m/s
2
or less
Uncertainty (K) : 1.5 m/s
2
ENG901-1
•
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.