![background image](http://html1.mh-extra.com/html/makita/hr3541fc/hr3541fc_technical-information_4244140009.webp)
P 9/ 19
R
epair
[5] DISASSEMBLY/ASSEMBLY
[5] -4. Active Dynamic Vibration Absorber
DISASSEMBLING
4x14 Tapping screw (2pcs.)
Crank cap cover
(1) Disassemble Crank housing cover. (Fig. 7)
Then remove Crank cap cover as illustrated in Fig. 15.
Fig. 15
Compression
spring 11
Spring guide
Absorber holder of
Crank housing complete
Pipe holder
Push Spring guide
(inner part of
Absorber).
Absorber holder
The Spring guide tilts to be
locked inside Absorber,
and the end of Absorber is
released from Crank housing
complete.
Disassemble Active dynamic
vibration absorber by levering up
with two Slotted screwdriver.
Active dynamic
vibration absorber
Phillips
screwdriver
Phillips
screwdriver
Slotted screwdriver
(2) Remove Active Dynamic Vibration Absorber from Crank housing complete as illustrated in Fig. 16.
And disassemble as illustrated in Fig. 17.
Fig. 16
Fig. 17
Pipe holder
Pipe holder
O ring 8
O ring 8
O ring 8
O ring 8
O ring 18
O ring 18
Compression spring 10
Compression spring 10
Spring guide
Pipe 15
Counter weight
Spring guide
Pipe holders can now be
separated by turning Pipe
holders while pushing
strong toward each other.