P 10/10
W
iring diagram
2) Handle L
1) Motor Housing
boss
rib on Motor housing
lead wire holder
on Motor housing
Switch
Route all lead wires between the rib and the boss.
Assemble Insulated connectors to
Switch terminals at such an angle
that the Insulated connectors do not
touch the rib.
Motor housing
Brush holder, right
Brush holder, left
lead wire holder
on Bush holder
red
black
Route two Lead wires (black, red) from Brush holder as illustrated in Fig. 30.
Fix with the lead wire holder
on Motor housing.
Do not route over the rib
on Motor housing.
Fix with the lead wire holder
on Brush holder.
Handle L
rib
rib
Terminal
Fig. 30
Fig. 31
The flag connector has to be so connected that
the wire connecting portion is positioned on
the side of pole marks of Terminal.
Flag connector
Terminal
Connecting Flag Connector to Terminal
Wire connecting portion
Pole mark