R
epair
(1) Replacing of armature
1)
Loosen the tapping screw PT4 x25 for mounting the
housing R to remove the housing R, and the fan 60 for
cooling the motor will be exposed.
2)
Loosen the tapping screw PT4 x25 for mounting the belt
cover to remove the belt cover.
3)
Disconnect the holder cap and then remove the carbon
brush.
4)
Remove the synchro belt 6-300 and steel plate.
Housing R
Tapping screw
PT4x25(7 pieces)
Tapping screw
PT4x25(4 pieces)
Belt cover
Fan 60