R
epair
P 7 / 9
< 8 > Disassembling switch, controller and power supply cord
< 9 > Adjusting lever 40
The pivoting area of lever 40 has to be adjusted as illustrated in Fig. 9.
( 3 ) Assemble the bracket to which armature has been assembled, to motor housing as illustrated in Fig. 7 C.
Bracket
Armature
Tapping screws 4 x 25
Motor housing
Fig. 7 C
Tapping screws M4 x 18
( 1 ) Take off tapping screws 4 x 18, and inserting -screwdriver, separate handle cover from motor housing.
So, switch, controller, choke coil and power supply cord can be disassembled.
See Fig. 8 and 8 A.
- Screwdriver
Controller
Switch
Power supply
cord
Fig. 8
Fig. 8 A
Lever 40
Fig. 9