7
proper cut depth helps to reduce potential for dangerous
KICKBACKS which can cause personal injury.
Bevel cutting
2
3
1
008673
Positive stopper
Turn the positive stopper so that the arrow on it points
one of three positions (22.5°,45°,56°). Then, tilt the tool
base until it stops and secure the base with the lever. At
this time, the same angle as the one that the arrow
points is obtained.
Setting bevel angle
Loosen the lever and tentatively set the tool base at the
0°bevel angle, then tighten the lever securely.
Turn the positive stopper so that the arrow on it points
one of three positions (22.5°,45°,56°) that is equal to or
greater than the desired bevel angle.
Loosen the lever again and then tilt and secure the tool
base at the desired angle securely.
NOTE:
•
When changing the positive stopper's position,
loosening the lever and tilting the bevel angle to
less than the desired stopper position number
allows to change it.
•
When the arrow on the positive stopper points 22.5,
the bevel angle can be adjusted 0 - 22.5°;when the
arrow points 45, it can be adjusted 0 - 45°; when
the arrow points 56, it can be adjusted 0 - 56°.
Sighting
A
B
1
008674
For straight cuts, align the A position on the front of the
base with your cutting line. For 45° bevel cuts, align the
B position with it.
Switch action
1
008675
CAUTION:
•
Before plugging in the tool, always check to see
that the switch trigger actuates properly and
returns to the "OFF" position when released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
Electric brake
For model 5007NFA only
This tool is equipped with an electric blade brake. If the
tool consistently fails to quickly stop blade after switch
trigger release, have tool serviced at a Makita service
center.
The blade brake system is not a substitute for lower
guard. NEVER USE TOOL WITHOUT A FUNCTIONING
LOWER GUARD. SERIOUS PERSONAL INJURY CAN
RESULT.
Lighting the lamp (For models
5007NF,5007NFA)
1
008676
CAUTION:
•
Do not apply impact to the lamp, which may cause
damage or shorted service time to it.
•
Do not look in the light or see the source of light
directly.
The lamp lights up when the tool is plugged. The lamp
keeps on lighting until the tool is unplugged.
If the lamp does not light up, the mains cord may be
defective. The lamp is lit but the tool does not start even
if the tool is switched on, the carbon brushes may be
worn out, the motor or the ON/OFF switch may be
defective.
1. Lamp
1. Switch trigger
1. Base
1. Lever
2. Positive stopper
3. Arrow on
positive stopper
Summary of Contents for 5007N