4 ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model
BO4555
BO4556
BO4558
BO4557
Pad size
112mm ×102mm
Orbits per minute (min
-1
)
14,000
Dimensions (L x W x H)
131 mm x 112 mm
x 142 mm
131 mm x 112 mm x 141 mm
131 mm x 112 mm
x 137 mm
Net weight
1.1 kg
1.2 kg
1.0 kg
Safety class
/II
•
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
•
Specifications may differ from country to country.
•
Weight according to EPTA-Procedure 01/2014
Intended use
The tool is intended for the sanding of large surface of wood,
plastic and metal materials as well as painted surfaces.
Power supply
The tool should be connected only to a power supply of the
same voltage as indicated on the nameplate, and can only
be operated on single-phase AC supply. They are double-in
-
sulated in accordance with European Standard and can,
therefore, also be used from sockets without earth wire.
Noise
The typical A-weighted noise level determined accord
-
ing to EN62841:
Model BO4555
Sound pressure level (L
pA
) : 80 dB (A)
Uncertainty (K) : 3 dB (A)
The noise level under working may exceed 80 dB (A).
Model BO4556
Sound pressure level (L
pA
) : 82 dB (A)
Sound power level (L
WA
) : 93 dB (A)
Uncertainty (K) : 3 dB (A)
Model BO4557
Sound pressure level (L
pA
) : 76 dB (A)
Uncertainty (K) : 3 dB (A)
The noise level under working may exceed 80 dB (A).
Model BO4558
Sound pressure level (L
pA
) : 79 dB (A)
Uncertainty (K) : 3 dB (A)
The noise level under working may exceed 80 dB (A).
Wear ear protection
Vibration
The vibration total value (tri-axial vector sum) deter
-
mined according to EN62841:
Model BO4555
Work mode : sanding metal plate
Vibration emission (a
h
) : 2.5 m/s
2
or less
Uncertainty (K) : 1.5 m/s
2
Model BO4556
Work mode : sanding metal plate
Vibration emission (a
h
) : 3.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model BO4557,BO4558
Work mode : sanding metal plate
Vibration emission (a
h
) : 3.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
NOTE:
The declared vibration emission value has been
measured in accordance with the standard test method
and may be used for comparing one tool with another.
NOTE:
The declared vibration emission value may
also be used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual
use of the power tool can differ from the declared emission
value depending on the ways in which the tool is used.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it is
running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
General power tool safety warnings
WARNING:
Read all safety warnings, instruc
-
tions, illustrations and specifications provided with this
power tool.
Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury.
Save all warnings and instruc
-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
SANDER SAFETY WARNINGS
1.
Always use safety glasses or goggles. Ordinary
eye or sun glasses are NOT safety glasses.
2.
Hold the tool firmly.
3.
Do not leave the tool running. Operate the tool
only when hand-held.