background image

5

Function Panel Controls 

(cont’d)

8.  

Both CV IN: Bi-Polar Exponential control signal input for entire FUNCTION. Contrary to the Rise and    

 

 

Fall CV IN, BOTH has an Exponential response and Positive control signals   decrease total    

 

 

time while Negative control signals increase total time.  

9.  

Fall CV IN: Linear control signal input for Fall parameter. Positive control signals increase Fall Time. 

 

 

Negative control signals decrease Fall Time with respect to the Fall panel control.   

10.   Vari-Response Panel Control: Sets the response curve of the voltage function. Response is  

 

 

 

 

continuously variable from Logarithmic through Linear to Exponential to Hyper-Exponential. The  

 

 

Tick mark shows the Linear setting.  

11.     HANG IN: Gate or Pulse applied to this input will stop the circuit dead in its tracks. Use for  

 

 

 

 

programming S&H, Track and Hold, Stepped Functions, Stepped LFOs,  

 

 

 

 

 

 

synchronized Functions.  

12.   LED indicates activity within the circuit.   
13.   Non- Inverted Signal OUT: Non-inverted signal from the FUNCTION circuit. Buffered and capable of    
 

 

accurately driving a 4 way multiple. 8V peak to peak when Cycling. Otherwise this output will    

 

 

follow the amplitude of the input. 

14.   EOR/ EOC LED: Indicates the states of the EOR and EOC outputs. When RED EOC is HIGH and  

 

 

 

EOR is LOW. When Green EOR is HIGH and EOC is LOW.   

15.   End Of Rise OUT: Goes high at the end of the Rise portion of the function. 0V or 10V.  
16.   End Of Cycle OUT: Goes high at the end of the Cycle (or Falling) portion of the function. 0V or 10V.  
17.  Inverted Signal OUT: Inverted signal from the FUNCTION circuit. Buffered and capable of  accurately    
 

 

driving a 4 way multiple. 8V peak to peak when Cycling. Otherwise this output mirrors the input   

 

 

amplitude.   

1

3

5

9

15 16 17 

4

6

8

11

7

12

13

10

14

2

Summary of Contents for FUNCTION

Page 1: ...v2 3 ...

Page 2: ...FUNCTION Limited Warranty 2 Installation 3 Panel Controls 4 Overview 6 Patch Ideas 7 1 ...

Page 3: ...e products will be repaired or replaced at the option of Make Noise on a return to Make Noise basis with the customer paying the transit cost to Make Noise Please contact technical makenoisemusic com for Return To Manufacturer Authorization Make Noise implies and accepts no responsibility for harm to person or apparatus caused through operation of this product Please contact technical makenoisemus...

Page 4: ...rly installed into a Eurorack format modular synthesizer system case Go to http www makenoisemusic com systems shtml for examples of Eurorack Systems and Cases board connector cable on backside of module see picture below plug the bus board connector cable into the Eurorack style bus board minding the polarity so that the RED stripe on the cable is oriented to the NEGATIVE 12 Volt line on both the...

Page 5: ...nly during Falling portion 3 CYCLE LED Indicates CYCLE ON or OFF 4 CYCLE Button Causes the circuit to self cycle thus generating a repeating voltage function aka LFO Use for LFO Clock VCO 5 Rise Panel Control Sets the time it takes for the voltage function to ramp up CW rotation increases Rise Time 6 Rise CV IN Linear control signal input for Rise parameter Positive Control signals increase Rise T...

Page 6: ...uit dead in its tracks Use for programming S H Track and Hold Stepped Functions Stepped LFOs synchronized Functions 12 LED indicates activity within the circuit 13 Non Inverted Signal OUT Non inverted signal from the FUNCTION circuit Buffered and capable of accurately driving a 4 way multiple 8V peak to peak when Cycling Otherwise this output will follow the amplitude of the input 14 EOR EOC LED I...

Page 7: ...erent destinations in opposition 2 As FUNCTION is single channel design we included both EOR and EOC There is interesting things you could do with these outputs such as flams see patch tips Much like CH 1 and 4 on the MATHS multiple FUNCTIONs can also be used to program complex functions using EOR and EOC 3 The evolution in the circuit is the HANG input On Gate HIGH at the HANG IN the FUNCTION is ...

Page 8: ... Voltage Controlled Ramp Function LFO As above only the Rise parameter is set FULL CCW Fall parameter is set to at least NOON Fall parameter as well as the BOTH control voltage IN determines the rate VC LAG Slew Processor Portamento A signal applied to the Signal IN is slewed according to the RISE and FALL parameters Variable response from Log through Linear to Exponential as set by the Vari Respo...

Page 9: ... Strike IN Take output 2 the Flam from EOC patch to Optomix CH 2 Strike IN Apply Signal s to be Flammed at Optomix Signal IN 1 and 2 Monitor SUM out Flam control is performed with the Fall parameter Voltage Controlled Clock Divider Clock signal applied to Trigger IN is processed by a divisor as set by Rise parameter Increasing Rise sets divisor higher resulting in larger divisions Fall time adjust...

Reviews: