background image

 

 

BRAINS with a single PRESSURE POINTS: 

Note the single open "Close 4 Master" header, the BRAINS cable 

connected from "Points 1-4" header to EXPAND header, and the jumper on BRAINS set to "1PP.”

6

Jumper and Cable Connections: (con’t)

Jumpers

Points 5-8

Points 1-4

Brains

BRAINS with two PRESSURE POINTS:

Two is the maximum number of PRESSURE POINTS that can be attached to a single BRAINS. Note: the connections of "Points 

1-4" and "Points 5-8" to EXPAND headers the single open location on the "Master" PRESSURE POINTS' "Close 4 Master" headers; 

all three "Close 4 Master" locations open on the non-master PRESSURE POINTS, and the Jumper on BRAINS set to "2PP.”

Summary of Contents for Brains

Page 1: ...v2 5...

Page 2: ...2 BRAINS Limited Warranty 3 Installation 4 Jumpers and Cable Connections 5 Panel Controls 7 Overview 8 Tips Tricks 9 Patch Examples 10...

Page 3: ...s changing face plates or any other causes determined by Make Noise to be the fault of the user are not covered by this warranty and normal service rates will apply During the warranty period any defe...

Page 4: ...perly installed into a Eurorack format modular synthesizer system case Go to http www makenoisemusic com for examples of Eurorack Systems and Cases board connector cable on backside of module see pict...

Page 5: ...nd headers Two PRESSURE POINTS chained Note that the Close 4 Master headers are closed on the first unit will be on the right when installed in the case For three or four PRESSURE POINTS use 4 header...

Page 6: ...on t Jumpers Points 5 8 Points 1 4 Brains BRAINS with two PRESSURE POINTS Two is the maximum number of PRESSURE POINTS that can be attached to a single BRAINS Note the connections of Points 1 4 and Po...

Page 7: ...lls BRAINS to RUN and thus a Gate or voltage below 1V stops BRAINS 4 Direction Input Gate or voltage of at least 1V tells BRAINS to count Forward Gate or voltage below 1V tells BRAINS to Run Backward...

Page 8: ...nalog sequencer Binary control over Direction of the stage selection RUN Stop and Reset are provided Touch Clock Input T CLK is normaled high and controls whether PRESSURE POINTS stages can be selecte...

Page 9: ...PRESSURE POINTS 3 4 5 6 to BRAINS Reset Input Touch the plate of the stage AFTER the one with Gate applied to Reset Input Watch sequencer jump over stage Combine multiple stages to Reset for longer ju...

Page 10: ...hla 250e Style Movement Patch MATHS CH 1 EOR to Clock Input BRAINS Set MATHS to Cycle Rise panel control to Noon Fall will set upper limit of clock rate Sequence should be running Patch the bottom mos...

Page 11: ...e Mult the bottom most row of Tuned Voltages from PRESSURE POINTS the same row controlling stage length to MATHS CH 3 Input Set CH 3 Scale Inversion to Full CCW Apply output of CH 3 to MATHS CH 4 BOTH...

Reviews: