UEG, MARF, ARF like: 

Begin with the Buchla 250e Style Movement patch.  Now patch the output of the middle row of Tuned Voltages to MATHS CH. 4 

Signal Input.  Set Rise and Fall panel controls to 12:00.  Set Response to Linear.  Signal Output on MATHS CH. 4 is your CV output, 

patch it to VCO, VCA, VCF, you know the game!  Mult the bottom-most row of Tuned Voltages from PRESSURE POINTS (the same 

row controlling stage length), to MATHS CH. 3 Input.  Set CH. 3 Scale/Inversion to Full CCW.  Apply output of CH. 3 to MATHS CH. 4 

BOTH Control Input.  Sequence runs at a rate determined by the bottom row.  The control signal generated by the sequence is 

interpolated according to the length of the stage, as set by the bottom most row of PP/BRAINS.  Additionally, try combining this 

patch with Single Shot patch to achieve a touch-triggered, multi-stage envelope. 

Summary of Contents for Brains

Page 1: ...v2 5...

Page 2: ...2 BRAINS Limited Warranty 3 Installation 4 Jumpers and Cable Connections 5 Panel Controls 7 Overview 8 Tips Tricks 9 Patch Examples 10...

Page 3: ...s changing face plates or any other causes determined by Make Noise to be the fault of the user are not covered by this warranty and normal service rates will apply During the warranty period any defe...

Page 4: ...perly installed into a Eurorack format modular synthesizer system case Go to http www makenoisemusic com for examples of Eurorack Systems and Cases board connector cable on backside of module see pict...

Page 5: ...nd headers Two PRESSURE POINTS chained Note that the Close 4 Master headers are closed on the first unit will be on the right when installed in the case For three or four PRESSURE POINTS use 4 header...

Page 6: ...on t Jumpers Points 5 8 Points 1 4 Brains BRAINS with two PRESSURE POINTS Two is the maximum number of PRESSURE POINTS that can be attached to a single BRAINS Note the connections of Points 1 4 and Po...

Page 7: ...lls BRAINS to RUN and thus a Gate or voltage below 1V stops BRAINS 4 Direction Input Gate or voltage of at least 1V tells BRAINS to count Forward Gate or voltage below 1V tells BRAINS to Run Backward...

Page 8: ...nalog sequencer Binary control over Direction of the stage selection RUN Stop and Reset are provided Touch Clock Input T CLK is normaled high and controls whether PRESSURE POINTS stages can be selecte...

Page 9: ...PRESSURE POINTS 3 4 5 6 to BRAINS Reset Input Touch the plate of the stage AFTER the one with Gate applied to Reset Input Watch sequencer jump over stage Combine multiple stages to Reset for longer ju...

Page 10: ...hla 250e Style Movement Patch MATHS CH 1 EOR to Clock Input BRAINS Set MATHS to Cycle Rise panel control to Noon Fall will set upper limit of clock rate Sequence should be running Patch the bottom mos...

Page 11: ...e Mult the bottom most row of Tuned Voltages from PRESSURE POINTS the same row controlling stage length to MATHS CH 3 Input Set CH 3 Scale Inversion to Full CCW Apply output of CH 3 to MATHS CH 4 BOTH...

Reviews: