56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] · www.majorcom.fr
56, chemin de la Flambère · 31300 Toulouse · FRANCE · T é l . 3 3 ( 0 ) 5 6 1 3 1 8 6 8 7
F a x 3 3 ( 0 ) 5 6 1 3 1 8 7 7 3 · [email protected] · www.majorcom.fr
8
9
EMAGP16
EMAGP16
Usermanual V1.1
Usermanual V1.1
•
Program the operation and settings of the paging console unit from
the PAGERS/DUCKERS tab of the ePXN1616 web application (see
ePXN1616 web application manual)
•
For maximum sound quality and minimum background noise, use
a screwdriver to set the ADJ control on the side of the unit to a
high level (increase it by turning clockwise) and the GAIN control
on the rear panel of the ePXN1616 (the one associated with the
PAGER A or B port to which the station is connected) to a low
level. You can start from a state with ADJ to maximum and GAIN
to minimum and adjust them following the above indications
until you get the desired signal levels to broadcast the paging
messages in the destination zones.
The maximum lengths for CAT5 or higher cabling connecting a station to
an ePXN1616 unit depend on the AWG category of the cable used. Exa
-
mples:
AWG24 Cable
AWG23 Cable
AWG22 Cable
Max. length 90 me-
ters
Max.
length
110
meters
Max.
length
140
meters
If the cable is too long, the paging station may work properly but noise will be superimposed on
the signal picked up by the microphone. The solution to this possible problem is to supply the
paging station with an external power supply.
WP24-PSU model
. The digital data exchange
between the ePXN1616 unit and the EMAGPE16paging station, using an external power supply
and good quality CAT5E cable, has been successfully tested with a wiring distance of 600 me
-
ters.
1.1.
Installation with PXN88 matrix
1.1.1.
Installation and
wiring
To install an EMAGPE16unit, connected to a PXN88, PXN88SG or PXN1212SG unit,
in CAN bus mode
, follow these steps:
•
Remove the back cover of the unit by unscrewing the screws that
hold it to the chassis to gain access to the connectors inside:
o
RJ45 connector
(1)
: connect a CAT5 or higher cable from
this connector to the REMOTE 1 or REMOTE 2 port of the
PXN88, or to the REMOTE port of PXN88SG or PXN1212SG
matrices. If other EMAGPE16or WPTOUCH digital devices
must be connected to the same port, in daisy chain topo
-
logy, the included RJ45 to screw terminals adapter can be
used.
REMOTE ports in the back panel of PXN matrices