Program the operation and settings of the paging console unit from 

the PAGERS/DUCKERS tab of the ePXN1616 web application (see 

ePXN1616 web application manual)

• 

For maximum sound quality and minimum background noise, use 

a screwdriver to set the ADJ control on the side of the unit to a 

high level (increase it by turning clockwise) and the GAIN control 

on the rear panel of the ePXN1616 (the one associated with the 

PAGER A or B port to which the station is connected) to a low 

level. You can start from a state with ADJ to maximum and GAIN 

to  minimum  and  adjust  them  following  the  above  indications 

until you get the desired signal levels to broadcast the paging 

messages in the destination zones.

The maximum lengths for CAT5 or higher cabling connecting a station to 

an ePXN1616 unit depend on the AWG category of the cable used. Exa

-

mples:

AWG24 Cable

AWG23 Cable

AWG22 Cable

Max. length 90 me-

ters

Max.

 

length

110

 

meters

Max.

 

length

140

 

meters

 

 

If the cable is too long, the paging station may work properly but noise will be superimposed on 

the signal picked up by the microphone. The solution to this possible problem is to supply the 

paging station with an external power supply. 

WP24-PSU model

. The digital data exchange 

between the ePXN1616 unit and the EMAGPE16paging station, using an external power supply 

and good quality CAT5E cable, has been successfully tested with a wiring distance of 600 me

-

ters.

1.1. 

Installation with PXN88 matrix

1.1.1. 

Installation and

 

wiring

To install an EMAGPE16unit, connected to a PXN88, PXN88SG or PXN1212SG unit,

in CAN bus mode

, follow these steps:

• 

Remove the back cover of the unit by unscrewing the screws that 

hold it to the chassis to gain access to the connectors inside:

RJ45 connector 

(1)

: connect a CAT5 or higher cable from 

this connector to the REMOTE 1 or REMOTE 2 port of the 

PXN88, or to the REMOTE port of PXN88SG or PXN1212SG 

matrices. If other EMAGPE16or WPTOUCH digital devices 

must be connected to the same port, in daisy chain topo

-

logy, the included RJ45 to screw terminals adapter can be 

used.

REMOTE ports in the back panel of PXN matrices

Summary of Contents for EMAGP16

Page 1: ...www majorcom fr EMAGP16 USER MANUAL Manual to download in PDF format on...

Page 2: ...e is intended to alert the user to the presence of uninsulated dangerous vol tage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons T...

Page 3: ...nt This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications O...

Page 4: ...priorities pro grammable keys etc 5 INSTALLATION 5 1 Installation with ePXN1616 matrix To install an EMAGPE16unit connected to an ePXN1616 matrix RS 485 bus connection follow these steps Remove the b...

Page 5: ...N1616 unit depend on the AWG category of the cable used Exa mples AWG24 Cable AWG23 Cable AWG22 Cable Max length 90 me ters Max length 110 meters Max length 140 meters If the cable is too long the pag...

Page 6: ...the RJ45 to screw terminals adapter Right without it when no daisy chained units share the same REMOTE line EMAGPE16RJ45 connector pinout diagram CAN bus mode o Connect as well the audio from the pag...

Page 7: ...WP24 PSU power supply Generallyspeaking theREMOTEport s ofaPXNmatrixcandirectlyfeedDC supply to a maximum of 2 EMAGPE16units but when wiring distances are really long the inrush current peak when the...

Page 8: ...station F1 and F2 keys zone group selection keys ALL key selects all zones that are enabled for the paging station equivalent to pressing individually all enabled zone keys CLR key disables all select...

Page 9: ...red for the zones to which the highest priority paging station is transmitting the message and which were not also selected on the Lowest priority station When the PAGE key is released on the priority...

Page 10: ...his process takes a few seconds to be carried out while the message UPGRADING FIRMWARE will be displayed accompa nied by the orange LED on the PAGE key When connecting an EMAGPE16paging station to the...

Page 11: ...B SPL with ADJ MAX 10dBV 94dB SPL with ADJ MID 20dBV 94dB SPL with ADJ MIN Digital characteristics Number of paging zones 16 Additional control keys F1 F2 All Clear Indicators Green LED on All and Cle...