Majorcom: AES24V MS40 User Manual Download Page 2

3

EN54-4 CERTIFIED POWER SUPPLY UNITS

AES24V

2

AES24V

EN54-4 CERTIFIED POWER SUPPLY UNITS

5 6 ,  c h e m i n   d e   l a   F l a m b è r e   •   3 1 3 0 0   To u l o u s e   •   F R A N C E   •   T é l .  3 3   ( 0 ) 5   6 1   3 1   8 6   8 7 
Fa x   3 3   ( 0 ) 5   6 1   3 1   8 7   7 3   •   c o m m e r c i a l @ m a j o r c o m . f r   •   w w w . m a j o r c o m . f r

5 6 ,  c h e m i n   d e   l a   F l a m b è r e   •   3 1 3 0 0   To u l o u s e   •   F R A N C E   •   T é l .  3 3   ( 0 ) 5   6 1   3 1   8 6   8 7 
Fa x   3 3   ( 0 ) 5   6 1   3 1   8 7   7 3   •   c o m m e r c i a l @ m a j o r c o m . f r   •   w w w . m a j o r c o m . f r

User manual

User manual

INTRODUCTION

TABLE OF CONTENTS

This manual includes instructions for the installation, commissioning and maintenance of this equipment.

In order for the equipment to work properly, we recommend to carefully follow these instructions.

SAFETY PRECAUTIONS

This equipment is designed to be connected to the 230 V public distribution network.

To avoid any risk of electric shock, 

all INTERVENTIONS must be carried out with the equipment SWITCHED OFF 

(

upstream two-pole circuit-breaker open).

Interventions with the equipment switched on are authorized only when it is impossible to switch the equipment off. The

operation must only be performed by qualified personnel.

STANDARDS, DIRECTIVES AND PROTECTION OF THE ENVIRONMENT AND PUBLIC HEALTH

This product is compliant with LV and EMC directives (immunity and emission). It is compliant with standards EN60950-1 

(2006), EN61000-6-1 (2007), EN61000-6-2 (2006), EN61000-6-3 (2007), EN61000-6-4 (2007), and EN 55022 class B 

(2007).

It is also compliant with the following trade standards :

• 

EN 54-4 (December 1997) and amendment A2 (February 2006): Fire detection and fire alarm systems. Part 4: 

power supply equipment.

• 

EN 12101-10 class A (January 2006): Smoke and heat control systems. Part 10: power supplies.

• 

EN 60849 (August 1998): Sound systems for emergency purposes (Paragraph 5.6).

The CPD CE Numbers is XXXXX, it was affixed in 2011.

These products have been manufactured in accordance with RoHS and WEEE environmental directives.

WARRANTY

This product is guaranteed for 24 (twenty four) from date of delivery. The battery is not included in the warranty.

1. GENERAL INFORMATION ...........................................................................................4

1.1 Front face ................................................................................................................................4

1.2 Environmental specifications

 ...................................................................................................4

1.3 Electrical input and output specifications

 ................................................................................4

•  1.3.1 Network input .............................................................................................................................4

•  1.3.2 Output ........................................................................................................................................4

• 

1.3.3 Specific features and technical specifications

 ...........................................................................5

• 

1.3.4 Authorized batteries

 ...................................................................................................................5

2. INSTALLATION OF YOUR EQUIPMENT ....................................................................6

2.1 Mounting..................................................................................................................................6

2.2 Batteries ..................................................................................................................................6

3. CONNECTION ...............................................................................................................7

3.1 Connection diagram ................................................................................................................7

3.2 Connection specifications

........................................................................................................7

4.  COMMISSIONING ........................................................................................................8
5. POWER SUPPLY OPERATION ....................................................................................9

5.1 Alarms .....................................................................................................................................9

5.2 Summary of available equipment ............................................................................................9

6. MAINTENANCE ...........................................................................................................10
7. FUSE PROTECTIONS ................................................................................................ 11
8. TROUBLESHOOTING PROCEDURE .......................................................................12
9. TECHNICAL SPECIFICATIONS ................................................................................13

Summary of Contents for AES24V MS40

Page 1: ...l a Fl a mb re 31300 To u l o u s e FR ANCE T l 33 0 5 61 31 86 87 Fax 33 0 5 61 31 87 73 co mmerc i a l ma j o rco m fr w w w majorcom fr User manual AES24V MS40 AES24V MS150 POWER SUPPLY UNITS USER...

Page 2: ...d EMC directives immunity and emission It is compliant with standards EN60950 1 2006 EN61000 6 1 2007 EN61000 6 2 2006 EN61000 6 3 2007 EN61000 6 4 2007 and EN 55022 class B 2007 It is also compliant...

Page 3: ...tage Default 1 2 3 Model AES24V MS40 AES24V MS150 Power voltage 195 264VAC 50 60Hz Primary Current 1A 195VAC 2A 195VAC Breaker Circuit D curve need to be provided Upstream Model AES24V MS40 AES24V MS1...

Page 4: ...e battery mesh every 4 hours The trigger threshold of the fault is 50 m 10 The trigger threshold of the fault is 13 m 10 Exceeding this threshold is signalled by a battery fault and means that the pow...

Page 5: ...User manual User manual 4 COMMISSIONING Connect the battery wires to the terminal strip but do not connect the battery terminals After the electrical connections are made mains loads and batteries 1...

Page 6: ...ry test is performed in the following manner every 30 seconds for the first 20 minutes after commissioning every 15 minutes after the first 20 minutes If a fault is detected the test is performed ever...

Page 7: ...ed clean and ensure that it is installed in a dry and ventilated location We shall in no case be liable for damages associated with improper use or incorrect maintenance of the equipment WARNING Repla...

Page 8: ...or equal to 11 5 Vdc Repeat the measurement after having disconnected the load and the battery Recheck the signalling of the indicator lights see chapter 5 If all the steps are validated check the co...

Page 9: ...a Fl a mb re 31300 To u l o u s e FR ANCE T l 33 0 5 61 31 86 87 Fax 33 0 5 61 31 87 73 co mmerc i a l ma j o rco m fr w w w majorcom fr AES24V MS40 AES24V MS150 POWER SUPPLY UNITS User manual MAJORC...

Reviews: