I. 

Avoid  installing  the  unit  in  direct  sunshine 

zones  or  where  air  stream  and  temperature 

have 

obvious 

alteration, 

connect 

line 

according to the right fig. 

        N 

– blue (Neutral) 

        L 

– brown (Live) 

.  1  Please  shut off  the  power  before  installation. 

(See following diagram) 

2 please tighten off the screw on the rear lid of 

junction box. 

3 Please connect the power into sensor lamp according to connection figure. 

4 Please install the sensor lamp on the selected position according to installation diagram.   

5 please cover the rear lid and tighten the screw. Then you can test it after electrifying. 

 

 

 

Test: 

1) 

Sensitivity: Adjust the knob “1” clockwise to raise its sensitivity and anti-clockwise to reduce 

its sensitivity. 

2) Adjust the knob

2

  clockwise to last operating time and anti-clockwise to shorten it . 

3) Light control: Adjust the knob

3

to select different working ambient-light.(See Fig.) 

4) Switch on the power, the lamp will turn on within 5s and go out within 5~30s;after 10s it will 

be on again 

5) Turn  the  light-control  to  night,  cover  the  detection  window  with  the  opaque  object,  the  lamp 

should be on, then go out after 5~10s. 

6) If  the  function  above-mentioned  is  normal,  you  can  set  the  light-control,  sensitivity  and 

time-delay according to your demand, then electrify to use it. 

Note: 

Avoid install it where there is sunshine or air stream and temperature change obviously, 

Avoid  touching  the  lens  device  with  sharp  things  and  coarse 

pollutant. 

                                     

MAJOR TECH (PTY LTD

 

Head Office:

 

Cnr Rover & Jaguar Roads, Rustivia Ext 3,

 

 

output   red(A)

infrared motion sensor

load

~input

brown(L)

blue(N)

1

2