background image

 

12 

RJ45 jack on the master unit marked with a ' 

  ' and 

the other end of the cable into the remaining receiving 

RJ45 jack. 

2.  Slide power switch on. The upper row of LEDs will start 

to scan in sequence if the Auto/Manual button is set on 

"Auto" mode. The LED for pin 1 will light up if the button 

is in "Manual" mode. 

3.  Switch back and forth from Auto or Manual scanning 

mode by pressing the Auto/Manual button on the side of 

the master-testing unit. 

4.  Once both ends of the cable are plugged in properly, the 

second row of LEDs will illuminate according to the 

corresponding LEDs in the top row. 

5.  Read the results of the LED display for the pin 

configuration status of the tested cable. If you fail to 

read the results the first time in Auto mode, you may 

wait for the second LED scan, or simply switch to 

Manual mode for pin by pin testing. In Manual mode, 

pressing the square "Test" button will advance testing to 

the next pin. 

 

RJ11 Modular Cable Test 

Please follow directions for the UTP/STP Cable Test and 

use the operations manual for the correct LED pin out 

display 

 

Coaxial Cable Test 

1.  Plug the two attached BNC adapter cables on both 

RJ45 jacks. Then connect the tested cable to each end 

of the BNC adapter cables

 

2.  For the remaining testing procedures, please refer to 

10Base-T Test steps 2 to 5.

 

Note: 

1.  The center pin of BNC should be read on LED 2. 

Summary of Contents for MTC50

Page 1: ...Instruction Manual MTC50 2 in 1 LAN Tester Multimeter...

Page 2: ...2 Contents Introduction 3 Features 3 Safety Precautions 4 Meter Description 5 Electrical Specification 6 Operation 8 Multi Network Modular Cable Tester 11...

Page 3: ...ster Multimeter Measures DC AC Voltage DC AC Current Resistance Continuity diode and LAN tester 3 digit 2000 count LCD display for multimeter functions LED Displays the actual pin configuration of 10...

Page 4: ...are properly closed and secured 3 Always disconnect the test leads from any voltage source before replacing the battery or fuses 4 Do not exceed the maximum rated input limits Input Limits Function M...

Page 5: ...r with LED display for receiving end 2 Jack RJ45 3 LAN connector 4 Jack RJ45 5 Jack RJ45 6 Led display for sourcing end Jack 1 Led display for receiving end Jack 2 7 Test switch for auto scan 8 LAN te...

Page 6: ...ications Function Range Accuracy DC Voltage 200mV 0 5 rdg 3d 2 000V 20 00V 1 0 rdg 3d 200 0V 600V 1 0 rdg 3d AC Voltage 50 60Hz 2 000V 20 00V 1 0 rdg 5d 200 0V 600V 1 5 rdg 10d DC Current 200 0 A 2000...

Page 7: ...Battery Indication BAT symbol indicates low battery condition Input Impedance 7 5M VDC VAC AC Response Average responding ACV Bandwidth 50Hz to 60Hz Auto Power Off 15 minutes approximately Fuse mA A...

Page 8: ...display AC DC CURRENT MEASUREMENTS 1 Set the function switch to the A mA position 2 Insert the black test lead into the negative COM terminal and the red test lead into the positive A mA terminal 3 Fo...

Page 9: ...stance reading 4 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch t...

Page 10: ...gain to return to normal operation Hold Button The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the display the HOLD indicator...

Page 11: ...e center board with the connectors and gently press into place 9 Replace and secure the rear cover battery and battery cover Multi Network Modular Cable Tester Operation The Multi Network Modular Cabl...

Page 12: ...the top row 5 Read the results of the LED display for the pin configuration status of the tested cable If you fail to read the results the first time in Auto mode you may wait for the second LED scan...

Page 13: ...switch to Auto mode for one person testing 3 Read the test results from the LED display on remote terminator Note The LED display on the remote unit will scan in sequence corresponding to the transmi...

Page 14: ...14...

Reviews: