background image

5

 

 

0.1V

 

 

0.5V

 

 

2.5V

 

 

10V

 

 

50V

 

 

250V 

 

 

1000V 

 

 

10V

 

 

50V

 

 

250V

 

 

1000V

 

 

50

μ

 

 

2.5mA

 

 

25mA

 

 

0.25A

 

 

x1

 

 

x10

 

 

x100

 

 

x1K

 

 

x10K

 

 

10V

 

 

50V

 

 

250V

 

 

x1

 

 

x10

 

 

x10 

DC Voltage

AC Voltage

DC Current

Resistance

Decibel

lceo

hFE

B 10
B 50
B 250
B 10
B 50
B 250
B 10
C 10
B 50
B 250
B 10
B 50
B 250
B 250
B 250
A
A
A
A
A
G
G
G
E
E
D

Test 

 

Range Position 

Scale to Read 

Multiplyer

x0.01
x0.01
x0.01
x1
x1
x1
x100
x1
x1
x1
x100
x1
x0.01
x0.1
x0.001
x1
x10
x100
x1000
x10000
x1
x1 + 14dB
x1 + 28dB
x1 (For big)
x1 (For small)
x1

Note:

The letter "A" to "G" in Scale to Read, please refer to Fig.01

DC 

AC 

DC 

AC 

Summary of Contents for MT832

Page 1: ...INSTRUCTION MANUAL ANALOGUE MULTIMETER MT832...

Page 2: ...2...

Page 3: ...Specifications 6 3 Meter Description 7 4 Operation 7 4 1 Resistance Test 8 4 2 Continuity Test Buzz and LED 8 4 3 DCV Test 8 4 4 ACV Test 9 4 5 Decibel 9 4 6 DCA Test 9 4 7 ACV Test on Output Termina...

Page 4: ...tance test Transistor test and hFE test 1 READ and UNDERSTAND all of the instructions and safety information in this manual before operating or servicing this instrument 2 Keep this instruction manual...

Page 5: ...l lceo hFE B 10 B 50 B 250 B 10 B 50 B 250 B 10 C 10 B 50 B 250 B 10 B 50 B 250 B 250 B 250 A A A A A G G G E E D Test Range Position Scale to Read Multiplyer x0 01 x0 01 x0 01 x1 x1 x1 x100 x1 x1 x1...

Page 6: ...5mA 0 25A x1 0 2 up to 2k Mid scale at 20 x10 2 up to 20k Mid scale at 200 x100 20 up to 200k Mid scale at 2k x1k 200 up to 2M Mid scale at 20k x10k 2k up to 20M Mid scale at 200k 150 A 1 5mA 15mA 150...

Page 7: ...erminal COM COMMON 8 Measuring Terminal 9 Plastic Protection Cover 3 METER DESCRIPTION 4 OPERATION WARNING 1 Before using this instrument please adjust the ZERO by Zero Corrector 2 When measuring the...

Page 8: ...cket Red lead 2 Set the range function switch to BZ CONT Y position apply the test lead pins to two points to be tested While tested circuit is continuous it should indicate to you as below A Buzz and...

Page 9: ...from the circuit under test then open up the circuit at the point where you wish to measure current Fig 04 4 Read the DCV A scale converted with the reference table Reset the function switch to succe...

Page 10: ...the full scale it means that the transistor is not good Otherwise it is a good transistor 4 9 hFE DC AMPLIFICATION TEST 1 Insert the test leads into COM Black lead and socket Red lead 2 Set the functi...

Page 11: ......

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...