background image

4

1. FEATURES

1. 8 Functions 20 measuring ranges.
2. Fuse and diode protection
3. Functions: AC/DC Voltage test, DC Current test, Resistance test, 

Transistor test and hFE test

 

1. READ and UNDERSTAND all of the instructions and safety 

information in this manual before operating or servicing this 
instrument!

2. Keep this instruction manual handy all the time, it will help 

you use this instrument easily in the future!

2. SPECIFICATIONS
2.1. REFERENCE TABLE FOR READING

Summary of Contents for MT832

Page 1: ...INSTRUCTION MANUAL ANALOGUE MULTIMETER MT832...

Page 2: ...2...

Page 3: ...Specifications 6 3 Meter Description 7 4 Operation 7 4 1 Resistance Test 8 4 2 Continuity Test Buzz and LED 8 4 3 DCV Test 8 4 4 ACV Test 9 4 5 Decibel 9 4 6 DCA Test 9 4 7 ACV Test on Output Termina...

Page 4: ...tance test Transistor test and hFE test 1 READ and UNDERSTAND all of the instructions and safety information in this manual before operating or servicing this instrument 2 Keep this instruction manual...

Page 5: ...l lceo hFE B 10 B 50 B 250 B 10 B 50 B 250 B 10 C 10 B 50 B 250 B 10 B 50 B 250 B 250 B 250 A A A A A G G G E E D Test Range Position Scale to Read Multiplyer x0 01 x0 01 x0 01 x1 x1 x1 x100 x1 x1 x1...

Page 6: ...5mA 0 25A x1 0 2 up to 2k Mid scale at 20 x10 2 up to 20k Mid scale at 200 x100 20 up to 200k Mid scale at 2k x1k 200 up to 2M Mid scale at 20k x10k 2k up to 20M Mid scale at 200k 150 A 1 5mA 15mA 150...

Page 7: ...erminal COM COMMON 8 Measuring Terminal 9 Plastic Protection Cover 3 METER DESCRIPTION 4 OPERATION WARNING 1 Before using this instrument please adjust the ZERO by Zero Corrector 2 When measuring the...

Page 8: ...cket Red lead 2 Set the range function switch to BZ CONT Y position apply the test lead pins to two points to be tested While tested circuit is continuous it should indicate to you as below A Buzz and...

Page 9: ...from the circuit under test then open up the circuit at the point where you wish to measure current Fig 04 4 Read the DCV A scale converted with the reference table Reset the function switch to succe...

Page 10: ...the full scale it means that the transistor is not good Otherwise it is a good transistor 4 9 hFE DC AMPLIFICATION TEST 1 Insert the test leads into COM Black lead and socket Red lead 2 Set the functi...

Page 11: ......

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: