background image

Select Working Mode
Working Mode:

 

• 

There are 31 working modes in this gauge. Measurement  data will not be 

stored when the gauge is in  Group0 measurement  mode.

• 

In the other 30 working modes, 30 measured data can be  stored in each 

mode cycle.

 

1.  Press the 

SELECT

 button to enter the 

MENU

 

2.  Press the 

UP/DOWN

 button to select WORKING MODE

 

3.  Press the 

SELECT

 button to enter WORKING MODE

 

4.  Press the 

UP/DOWN

 button to select WORKING MODE

 

5.  Press the 

SELECT

 button for 

OK

.

Select Measure Mode (Probe)

The probe has 3 (three) different modes:

AUTO:

   T

  he probe can automatically select the working mode. When placed 

on steel (magnetic substrates), it will    work in   magnetic induction 
principle.    When placed on no-ferrous metals, it will work in eddy 
current principle.

Fe:

   

The probe works in magnetic induction principle. 

No-Fe:

  The probe works in eddy current principle.

 

1.  Press the 

SELECT

 button to enter the 

MENU

 

2.  Press the 

UP/DOWN

 button to select WORKING MODE

 

3.  Press the 

SELECT

 button to enter WORKING MODE

 

4.  Press the 

UP/DOWN

 button to select WORKING MODE

 

5.  Press the 

SELECT

 button for 

OK

.

Settings

Select Unit

1.  Press the 

SELECT

 button to enter the 

MENU

2.  Press the 

UP/DOWN

 button to 

SELECT THE SETTING

3.  Press the 

SELECT

 button to 

ENTER THE SETTING

4.  Press the 

UP/DOWN

 button to 

SELECT UNIT

5.  Press the 

SELECT

 button to 

ENTER

6.  Press the 

UP/DOWN

 button to 

SELECT

7.  Press the 

SELECT

 button for 

OK

Backlight Brightness Setting

1.  Press the 

SELECT

 button to enter the 

MENU

2.  Press the 

UP/DOWN

 button to 

SELECT THE SETTING

3.  Press the 

SELECT

 button to 

ENTER THE SETTING

4.  Press the 

UP/DOWN

 button to 

SELECT BACKLIGHT

5.  Press the 

SELECT

 button to 

ENTER

6.  Press the 

UP/DOWN

 button to adjust the brightness of the 

BACKLIGHT

7.  Press the 

BACK

 button to 

RETURN

.

Summary of Contents for MT155

Page 1: ...INSTRUCTION MANUAL COATING THICKNESS METER MT155 ...

Page 2: ...ble to specific tasks for instance they can be used on special geometries or on materials with special properties You can select the probe mode via the MENU system Introduction Features Ÿ Measured Coatings 1 Non magnetic coatings e g paint zinc on steel 2 Insulating coatings e g paint anodizing coatings on no ferrous metals Ÿ Easy to operate MENU Ÿ Memory for 1500 readings Ÿ Delete single readings...

Page 3: ...ly The gauge will take faulty measurements if the voltage is low Note When the power is on keep away from any metal at least 10cm away before each measurement zero calibration is recommended Ready to Start 1 Switch off the tester remove the battery cover and remove batteries 2 Insert new batteries observing correct polarity and close the cover Replace the batteries when the symbol is displayed Use...

Page 4: ...magnetic induction principle No Fe The probe works in eddy current principle 1 Press the SELECT button to enter the MENU 2 Press the UP DOWN button to select WORKING MODE 3 Press the SELECT button to enter WORKING MODE 4 Press the UP DOWN button to select WORKING MODE 5 Press the SELECT button for OK Settings Select Unit 1 Press the SELECT button to enter the MENU 2 Press the UP DOWN button to SEL...

Page 5: ...TTING 4 Press the UP DOWN button to SELECT GRAY SCALE 5 Press the SELECT button to ENTER 6 Press the UP DOWN button to ADJUST GRAY SCALE 7 Press the SELECT button for OK System Information System version number 1 Press the SELECT button to enter the MENU 2 Press the UP DOWN button to SELECT THE SETTING 3 Press the SELECT button to ENTER THE SETTING 4 Press the UP DOWN button to SELECT INFORMATION ...

Page 6: ... SELECT CALIBRATION 3 Press the SELECT button to ENTER CALIBRATION 4 Press the UP DOWN button to delete the ZERO POINT of Fe or Non Fe 5 Press the SELECT button for OK 6 Press the BACK button to RETURN Delete Functions In MENU system you can find following function Delete current data in measurement interface you can delete the last data entry by pressing the BACK button Delete all data Enter menu...

Page 7: ... 3 5 39 3 53 1mils 3 5 Minimum curvature radius 1 5mm 3 0mm Diameter of Minimum area 7 0mm 5 0mm Minimum measurable thickness 0 5mm 0 3mm Overload display Precision 0 100um 0 1urn 0 100um 0 1urn 100um 1000um 1um 100um 1000um 1um 1000um 1350um 0 01 mm 0 10mils 0 01mils 10 53 1mils 0 1mils 1000um 1350um 0 01 mm 0 10mils 0 01mils 10 53 1mils 0 1mils Working temperature Working relative humidity Dimen...

Page 8: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia ...

Reviews: