IntelliFire Touch - (continued)

Symptom

Possible Cause

Corrective Action

Pilot sparks but does not light, after 

90 sec, 3 Red/1 Green Lockout

No gas supply.

Verify incoming gas line ball valve is ‘Open’.  Verify inlet pres-

sure is within requirement for gas type used.  Contact gas sup-

plier.

ECM has poor ground.

Verify  wiring,  check  valve  harness  black  wire  is  securely 

grounded to metal chassis.

Gas valve defective.

Check pilot valve solenoid kick and hold voltages during igni

-

tion cycle.  Kick V should be >1 V, hold V minimum 0.26 V.  If 

voltages are OK, replace gas valve.

Pilot lights but main burner does 

not light.   Pilot continues to spark 

for 90 sec then goes into 3 Red/1 

Green Lockout.

No flame detected. Flame 

rectification issue.

Check if white sense lead is securely connected to ‘S’ terminal 

of IFT-

ECM.  Check resistance of sense lead between sense 

rod tip and connector to IFT-ECM, should be less than 1 ohm 

- if not, replace pilot assembly.  Check system ground, ensure 

black valve harness wire is securely attached to metal chassis.  

Check wiring for damage.  With system OFF, check resistance 

between tip of sense rod and pilot hood, should be resistance 

(>1 M-ohm). 

No flame detected or sense 

rod contamination. 

With  glass  assembly  installed,  verify  pilot  flame  is  engulfing 

flame sense rod on pilot assembly.  Verify inlet gas pressure 

is correct for gas type.  Polish flame sense rod with fine steel 

wool to remove any contaminants that may have accumulated.

Pilot lights and rectifies, but main 

burner does not light.

Main valve solenoid.

Check  if  green  wire  in  valve  harness  is  connected  to  green 

main valve solenoid.  Check main valve solenoid resistance, 

nominal is 60 ohms.  If open or shorted, replace valve.  Verify 

valve inlet pressure is correct for gas type.

Pilot and main do not light, ECM 

goes into 5 Red/1 Green Lockout.

Power Vent (PV) Failure.

Power Vent blower defective - check wiring to 

IFT-

ACM, check 

if blower is working.  Check if PV pressure switch is connected 

to brown and black wire in 6-pin valve wire harness.  Check if 

pressure switch is closed (shorted) when PV blower is running.  

Refer to PV troubleshooting instructions. 

Appliance lights and runs for a few 

minutes then shuts down and/or 

appliance cycle ON and OFF with 

less than 90 sec of ON time. 

Shorted or loose connection in 

flame detection circuit.

Check if white sense lead is securely connected to ‘S’ terminal 

of IFT-

ECM.  Check resistance of sense lead between sense 

rod tip and connector to IFT-ECM, should be less than 1 ohm 

- if not, replace pilot assembly.  Check system ground, ensure 

black valve harness wire is securely attached to metal chassis.  

Check wiring for damage.  With system OFF, check resistance 

between tip of sense rod and pilot hood, should be resistance 

(>1 M-ohm). 

Poor flame rectification or 

contaminated sense rod. 

With  glass  assembly  installed,  verify  pilot  flame  is  engulfing 

flame sense rod on pilot assembly.  Verify inlet gas pressure 

is correct for gas type.  Polish flame sense rod with fine steel 

wool to remove any contaminants that may have accumulated.  

Verify no soot deposits are in sense rod to pilot hood gap.

Logs are set up wrong. 

Remove and re-install logs per the log placement instructions.

Damaged pilot assembly.

Verify  the  pilot  assembly  ceramic  insulator  around  the  flame 

sensing rod is not cracked, damaged or loose.  Check resis

-

tance between tip of sense rod and IFT-ECM connector, should 

be less than 1 ohm.  Replace pilot assembly if damage is de-

tected.

Summary of Contents for QUARTZPLA36IN

Page 1: ...unless a certified kit is used DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewin...

Page 2: ...t Approved Minimum De Gaz Acceptable x x in w c Po Col d eau Maximum Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pre...

Page 3: ...Specifications 6 C BTU Specifications 6 D High Altitude Installations 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall an...

Page 4: ...ipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years fr...

Page 5: ...pply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components no...

Page 6: ...u must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada B Glass Specifications This appliance is equipped with ceramic g...

Page 7: ...ildren will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire p...

Page 8: ...cording to the installation instructions Non combustible surfaces and mantels do not have a maximum temperature limit however the installation instructions must still be followed for any restrictions...

Page 9: ...9 Majestic QUARTZPLA36IN QUARTZPLA36IL Owner s Manual 2643 981 Rev B 7 22 G Lighting Instructions IPI...

Page 10: ...njunction with the IFT RC400 control The Heat Zone Gas Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management...

Page 11: ...nsert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 3 A complete wiring diagram is included in the Electrical section of the appliance Installation M...

Page 12: ...result of a system error When switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame settin...

Page 13: ...hese steps call your dealer for service Wi Fi Optional If desired a Wi Fi module IFT WFM may be added to allow the appliance to be run via an app Contact your dealer to order Fan The fan functions are...

Page 14: ...nt and Firebox Top Annually Pilot and Burner Ignition and Operation Annually LED Replacement As needed Electrical Service and Repair As needed Glass Cleaning Frequency Seasonally By Homeowner Tools Ne...

Page 15: ...tions for proper calibration and setup procedure Replace batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your firepl...

Page 16: ...ld be avoided Remove all foreign objects Verify unobstructed air circulation Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves v...

Page 17: ...Shock Replace damaged wire with type 105 C rated wire Wire must have high temperature insulation LED Replacement Frequency As needed By Qualified Service Technician Tools needed Protective gloves rep...

Page 18: ...nishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the cur...

Page 19: ...tween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the rem...

Page 20: ...DC adaptor faulty backup batteries if being used depleted IFT ECM slider switch in OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify...

Page 21: ...n main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes...

Page 22: ...Zone Gas Kit 6 6 Reference Materials A Accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional accessories with this appliance Using non listed accesso...

Page 23: ...6 Y 1 Rear Left Base Log SRV2414 709 2 Rear Right Base Log SRV2414 710 3 Front Left Base Log SRV2413 703 4 Front Right Base Log SRV2414 711 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 7...

Page 24: ...attery Pack SRV2326 134 Y 17 7 LED Controller 2166 336 Y 17 8 Module RF FCC SRV2326 120 Y 17 9 Module IFT Control SRV2326 130 Y 17 10 Module B Type AC SRV2326 150 Y 17 11 Harness IFT 6 Pin Wiring SRV2...

Page 25: ...ION COMMENTS PART NUMBER Exhaust Restrictor 530 299 Finishing Template SRVFS 6 Gasket Assembly 2118 080 Contains Burner neck shutter bracket vent seal cap valve plate ember LED and air passage gaskets...

Page 26: ...____________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible...

Reviews: