Majestic QUARTZPLA36IN Owner'S Manual Download Page 6

Majestic  • QUARTZPLA36IN / QUARTZPLA36IL Owner’s Manual  •  2643-981 Rev. B  •  7/22

6

A.  Appliance Certification

Product Specific Information 

 

MODELS:

  QUARTZPLA36IN / QUARTZPLA36IL

LABORATORY:  

Underwriters Laboratories, Inc. (UL)

TYPE:  

Direct Vent Heater

STANDARD:

  CSA / ANSI Z21.88-2019  •  CSA 2.33-2019

This product is listed to ANSI standards for “Vented 

Gas Fireplace Heaters” and applicable sections of “Gas 

Burning Heating Appliances for Manufactured Homes 

and Recreational Vehicles”, and “Gas Fired Appliances 

for Use at High Altitudes”.  Also Certified for Installation in 

a Bedroom or a Bedsitting Room.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance.  It should not be 

factored as primary heat in residential heating calculations.

NOTICE: 

This installation must conform with local codes. 

In the absence of local codes you must comply with the 

National  Fuel  Gas  Code, ANSI  Z223.1-latest  edition  in 

the U.S.A. and the CAN/CGA B149 Installation Codes in 

Canada.

B.  Glass Specifications

This appliance is equipped with ceramic glass. Replace 

glass only with ceramic glass. Please contact your dealer 

for replacement glass.

D.  High Altitude Installations

NOTICE: 

If the heating value of the gas has been reduced, 

these rules do not apply. Check with your local gas utility 

or authorities having jurisdiction.

When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet  

above 2000 feet.

•  In  CANADA:  Input  ratings  are  certified  without  a 

reduction of input rate for elevations up to 4500 feet 

(1370 m) above sea level. Please consult provincial and/

or local authorities having jurisdiction for installations at 

elevations above 4500 feet (1370 m).                                   

Check  with  your  local  gas  utility  to  determine  proper 

orifice size.

C.  BTU Specifications

Models

(U.S. or Canada)

Maximum

Input 

BTU/h

Minimum

Input BTU/h

Orifice

Size 

(DMS)

QUARTZPLA36IN

(NG)

(0-2000 ft)

30,500 15,000

#37

QUARTZPLA36IL

(Propane)

(0-2000 ft)

29,500 15,000

#52

Summary of Contents for QUARTZPLA36IN

Page 1: ...unless a certified kit is used DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewin...

Page 2: ...t Approved Minimum De Gaz Acceptable x x in w c Po Col d eau Maximum Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pre...

Page 3: ...Specifications 6 C BTU Specifications 6 D High Altitude Installations 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall an...

Page 4: ...ipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years fr...

Page 5: ...pply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components no...

Page 6: ...u must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada B Glass Specifications This appliance is equipped with ceramic g...

Page 7: ...ildren will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire p...

Page 8: ...cording to the installation instructions Non combustible surfaces and mantels do not have a maximum temperature limit however the installation instructions must still be followed for any restrictions...

Page 9: ...9 Majestic QUARTZPLA36IN QUARTZPLA36IL Owner s Manual 2643 981 Rev B 7 22 G Lighting Instructions IPI...

Page 10: ...njunction with the IFT RC400 control The Heat Zone Gas Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management...

Page 11: ...nsert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 3 A complete wiring diagram is included in the Electrical section of the appliance Installation M...

Page 12: ...result of a system error When switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame settin...

Page 13: ...hese steps call your dealer for service Wi Fi Optional If desired a Wi Fi module IFT WFM may be added to allow the appliance to be run via an app Contact your dealer to order Fan The fan functions are...

Page 14: ...nt and Firebox Top Annually Pilot and Burner Ignition and Operation Annually LED Replacement As needed Electrical Service and Repair As needed Glass Cleaning Frequency Seasonally By Homeowner Tools Ne...

Page 15: ...tions for proper calibration and setup procedure Replace batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your firepl...

Page 16: ...ld be avoided Remove all foreign objects Verify unobstructed air circulation Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves v...

Page 17: ...Shock Replace damaged wire with type 105 C rated wire Wire must have high temperature insulation LED Replacement Frequency As needed By Qualified Service Technician Tools needed Protective gloves rep...

Page 18: ...nishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the cur...

Page 19: ...tween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the rem...

Page 20: ...DC adaptor faulty backup batteries if being used depleted IFT ECM slider switch in OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify...

Page 21: ...n main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes...

Page 22: ...Zone Gas Kit 6 6 Reference Materials A Accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional accessories with this appliance Using non listed accesso...

Page 23: ...6 Y 1 Rear Left Base Log SRV2414 709 2 Rear Right Base Log SRV2414 710 3 Front Left Base Log SRV2413 703 4 Front Right Base Log SRV2414 711 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 7...

Page 24: ...attery Pack SRV2326 134 Y 17 7 LED Controller 2166 336 Y 17 8 Module RF FCC SRV2326 120 Y 17 9 Module IFT Control SRV2326 130 Y 17 10 Module B Type AC SRV2326 150 Y 17 11 Harness IFT 6 Pin Wiring SRV2...

Page 25: ...ION COMMENTS PART NUMBER Exhaust Restrictor 530 299 Finishing Template SRVFS 6 Gasket Assembly 2118 080 Contains Burner neck shutter bracket vent seal cap valve plate ember LED and air passage gaskets...

Page 26: ...____________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible...

Reviews: