background image

21

NVB Series B-Vent Gas Fireplace

7412950

NVB

 (continued)

  Ref.   Description 

NVB36 

NVB42

 

  Door Track - Brass 

3067102 

3072102

  11.  Side Brick - Left 

3030104 

3030104

  12.  Back Brick 

3030102 

3032102

  13.  Side Brick - Right 

3030160 

3030160

  14.  Ceramic Panel - Left 

3043132 

3051120

  15.  Ceramic Panel - Right 

3043133 

3051119

  16.  Glass 

7540637 

7540642

  17.  Grate 

20000612 

20000539

  18.  O.S.A. Assy. 

20003076 

20003076

  19a.  Valve Nova - Natural 

7529141 

7529141

  19b.  Valve Nova - LP 

7529142 

7529142

  20.  Piezo Ignitor 

52464 

52464

  21a.  Pilot Top Convertible - Natural (3 Way Assembly) 

10002264 

10002264

  21b.  Pilot Top Convertible - LP (3 Way Assembly) 

10002265 

10002265

  22.  Electrode Ignitor w/Cable 

10001297 

10001297

  23a.  Pilot Orifice - Natural 

10002268 

10002268

  23b.  Pilot Orifice - LP 

10002269 

10002269

  24.  Thermopile 18” 

7533113 

7533113

  25.  Pilot Tubing 

10001296 

10001296

  26.  Cable Ignitor 24” 

7522432 

7522432

  27.  Thermocouple 24” 

7531137 

7531137

  28a.  E. Valve - Natural 

57884 

57884

  28b.  E. Valve - LP 

57883 

57883 

  29a.  E. Pilot Assy. - Natural (4 Way) 

10002387 

10002387

  29b.  E. Pilot Assy. - LP (4 Way) 

10002388 

10002388

  30.  Sensing Electrodes 

57885 

57885

  31.  Ignition Device - Honeywell 

20000005 

20000005

  32.  Transformer 

7522409 

7522409

  33.  Air Shutter - Natural 

20000129 

20000129

  34.  Air Shutter - LP 

20000680 

20000680

  35.  Conversion Kit - Natural 

20003893 

20003893

  36.  Conversion Kit - LP 

20003894 

20003894

  37.  Hearth Cover Shield 

3043118 

3051121

Contact CFM Corporation for questions concerning prices and poli-
cies covering replacement parts. Parts may be ordered through your 
Majestic Fireplaces distributor or dealer.
You will need the following information when ordering replacement 
parts:
 

1.  The appliance model number.

 

2.  The serial number.

 

3.   A description of the part.

Should you need additional information beyond what your dealer 
can furnish, contact:  
CFM Corporation
410 Admiral Blvd.
Mississauga, Ontario, Canada L5T 2N6
Attn: Manager of Customer Service

Model and serial numbers are listed on the rat-
ing plate (located on right side of combustion 
chamber).

Record your model and serial numbers here for 
future reference:

Model #  

____________________________

Serial # 

____________________________

f i r e - p a r t s . c o m

Summary of Contents for NVBR36

Page 1: ...er Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch electrical switches 3...

Page 2: ...ntels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Speci cations 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Identi cation and Chase...

Page 3: ...the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of...

Page 4: ...59mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series speci cation and framing dimensions NVBC36 Series Gas Appliance Circulating Model...

Page 5: ...ssed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig 4 NVBC42 Series speci cation and framing dimensions NVBC42 Series Gas Appliance Circulating Model...

Page 6: ...ng F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Sur round Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installati...

Page 7: ...gnition 30 000 21 500 NVBC36EN Natural Electronic Ignition 30 000 21 500 NVBR36EP Propane Electronic Ignition 30 000 22 000 NVBC36EP Propane Electronic Ignition 30 000 22 000 NVBR42RN Natural Millivol...

Page 8: ...the appliance location has not been accomplished install the required pipe Consult local plumbing code to assure proper pipe size The gas pipeline can be brought in through the right side of the appl...

Page 9: ...ide a union so that gas line can be easily disconnected for burner or fan servic ing See gas speci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside of the ap...

Page 10: ...on excess wire completely within the EB1 Attach the cov erplate to the replace Fig 11 Fig 11 Junction box EB 1 hook up FP580 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Insi...

Page 11: ...ng configuration Unacceptable venting configuration FP567a Fig 14 Venting con gurations when installing 36GSKBB 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 2 4 6 8 10 12 14 16 18 20 A FP567a Ven...

Page 12: ...mes with a non ammonia household cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the cir...

Page 13: ...or units equipped with Hi Lo valves ame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Flame Characteristics It is important to periodicall...

Page 14: ...B Series B Vent Gas Fireplace 7412950 LG151 NVB36 log flames 2 2 01 djt Red Glow Embers LG151 Fig 19 NVB36 ame appearance LG150 NVB42 log flames 2 1 01 djt LG150 Fig 20 NVB42 ame appearance fire parts...

Page 15: ...or turn by hand do not try to repair it call a quali ed service technician Applying force or any attempted repair may result in a re or explo sion D Do not use this replace if any part has been under...

Page 16: ...h in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re...

Page 17: ...modisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot mete...

Page 18: ...ld cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay replace gas con...

Page 19: ...identical to taking care of the Standing Pilot models Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean At least once per year the logs and...

Page 20: ...3 5 Ceramic Tile single 57803 57803 6a Burner Ori ce Natural Manifold Ori ce 20003532 20003547 6b Burner Ori ce LP Manifold Ori ce 20003541 20003552 7 Thermodisk 20001558 20001558 8 Remote Switch Kit...

Page 21: ...Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 Air...

Page 22: ...Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic igni tion models Glass Doors Bi fold and single panel glass doors are availab...

Page 23: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Reviews: