19
Majestic • MERC32IN, MERC32IL, MERC32VN, MERC32VL Installation Manual • 2401-980 Rev. C • 11/16
Figure 4.11
Figure 4.10
V
1
= 60 ft. Max. (18.3 m)
2. Top Vent - Vertical Termination
No Elbows
EXHAUST BAFFLE
Top Vent Application
Rear Vent Application
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual
fl
ame height. If the vent con
fi
guration has
a total vertical of 15-60 feet, an exhaust restrictor may
be needed. The exhaust restrictor can be located in the
appliance manual bag.
Note
: Be sure to rein-
stall the exhaust baf
fl
e
after exhaust restrictor
installation.
Exhaust restrictor
Exhaust restrictor
Exhaust restrictor Instructions
1. Install the exhaust restrictor over the center of the ex-
haust outlet in the
fi
rebox. See Figure 4.11.
2. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the ex-
haust restrictor with the 2-1/4 in. self-tapping screws
provided in the appliance manual bag.
To access the exhaust
openings, remove the
exhaust baf
fl
e. To re-
move exhaust baf
fl
e, re-
move the two wing nuts.
Note:
If installing a vertical vent/termination off the top of
the appliance, the optional vertical termination baf
fl
e may
be needed.
Note: Use SLP Series
components only.
V
1