Figure 2.4 Good Faith Guidelines - Passive Heat Kit Installed
Good Faith Guidelines for TV Installations Above a Fireplace
with Passive Heat Option and an Optional Fan
*
Mesh screen required for front discharge or open top discharge passive heat installations with discharge opening of three inches or greater.
NOTE:
The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a top discharge, side
discharge, or open top discharge.
NOTICE: A mantel is required when both the Passive Heat option and an optional fan are installed.
Life expectancy of the TV will be reduced if a mantel is not present.
A mantel is not required when the Passive Heat option is installed and a fan is not present.
“A” Dimension taken from the front of TV to front of the mantel.
“B” Dimension taken from the top of mantel to bottom of TV.
“C” Dimension taken from the top of the appliance opening to the bottom of the TV.
“D” Minimum mantel depth = Wall bracket thi TV thi 3 inches
“E” Dimension taken from the top of TV to bottom of discharge opening.
“F” Passive Heat kit is installed with no mantel and no fan. Dimension from appliance opening to bottom of TV.
TV mounted flat
TV mounted at angle
TV Wall Bracket
Appliance
E
E
PASSIVE HEAT DISCHARGE OPENING
PASSIVE HEAT DISCHARGE OPENING
WIRE MESH*
A
B
C
C
B
A
Appliance
Opening
Appliance
Opening
D
D
C
B
A
ITEM MINIMUM DIMENSIONS
D
E
3 inches
4 inches
12 inches
12 inches
F
Mantel - required when
both Passive Heat and
Optional Fan are present.
Mantel - required when
both Passive Heat and
Optional Fan are present.
F
F
5-1/4 inch min. 6-1/4 inch max.
Wall Bracket Depth +
TV Thi 3 inches
Appliance
Notes:
1. These are good faith recommended clearances only and not a guarantee of compliance with all TV manufacturers’ maximum
allowable opera�ng
temperatures.
2. Since every home has unique ai
r flow characteris�cs and maximum allowable opera�ng temperatures can vary from manufacturer
to manufacturer and from model to model, actual TV tem
peratures should be validated at the �me of each installa�on.
TVs should not be used in situa�ons where the actual TV temperature exceeds the manufacturers’ maximum allowable opera�ng
temperatures iden�fied in the TV’s technical specifica�ons. Contact the TV’s manufacturer directly if you cannot locate this
informa�on or have ques�ons regarding the informa�on.
3. Mantel height and depth must conform to mantel
requirements
specified in the appliance installa�on manual.
4.
Sugges�ons on how to further reduce TV temperatures:
a. Increase “A” dimension.
b.
Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures.