Designer Series Gas Fireplaces
a. waLL LoCaTIoN
y
Minimum distance between a glass panel and a parallel
wall = 4"
Z
Minimum distance between the edge of a glass panel and
an adjacent wall = 3"
B. Island Location
x
(Maximum length of horizontal venting = 0'. Refer to the
venting section of this manual for specific dimensions.
INSTaLLaTIoN
Figure 7 -
Possible Fireplace Locations
FP77
A Flat on Wall
B Room Divider
X
X
X
A
B
Y
Y
Z
A
Y
FP2277
locate fireplace
SECuRE FIREPLaCE To FLooR
The fireplace must be secured to the floor and/or to framing
studs as shown in
Figure 8
. Use two () wood screws or
masonry/ concrete screws to secure fireplace to the floor.
Use four (4) screws to attach fireplace to framing. The side
brackets are adjustable from 1/" to 5/8" to accommodate
different thickness of noncombustible material.
FP2278
secure fireplace
Figure 8 -
Secure Fireplace to Floor and Framing Studs
Screws
FP78
CaNoPy INSTaLLaTIoN
1. Unlatch and remove glass door. Refer to Page 7.
. Remove three (3) top louvers by pulling firmly.
3. Locate screws on upper frame and remove.
(Five (5) screws on long side and three (3)
screws on short side.)
Figure 9
4. Install canopy hood and secure using
screws previously removed.
5. Reinstall louvers and glass door.
FP2918
canopy install
Figure 9 -
Install ALL Canopies
FP918
IMPoRTaNT:
Canopy hoods are furnished with this
fireplace and all of them MuST be installed for safe
operation.