background image

20000706

9

Fig. 7

  Chimney cap removal.

      

MD706-8

MD706-8

Chimney Cap Removal

1-21-99

••••••••••••

••••••••••••

•••••••••••••

•••••••••••••

RLTSK8L

RLTSK8  

••••••••••••

•••••••••••••

••••••••••••

T20B

(Arrows show screw locations)

Inspect the flue for creosote buildup. The chimney should 

be inspected at least once every two (2) months during 

the heating season. If 1/8” (3 mm) or more of creosote has 

accumulated, it should be removed to reduce the risk of a 

chimney fire. Special tools and expertise are required to 

clean a flue. It is recommended that a qualified chimney 

sweep provide this service. To gain access to the flue for 

inspection, and/or cleaning, the chimney cap or top housing 

need to be removed. Refer to Figure 7 to identify the style 

of the top housing. Remove screws as indicated.
5.  Inspect  the  firebox  hearth  and  firebrick  liner  for  any 

unusual deterioration or erosion.

The hearth and firebrick liner of your fireplace are made 

of a special fireclay material. While it is quite sturdy, it can 

become  cracked  by  normal  expansion  and  contraction 

from heat or abuse. If hairline cracks should develop in the 

hearth or firebrick liner, they can be ignored as they will 

nOT affect the operation or safety of your fireplace. 
Contact your Vermont Castings Group Dealer if repair or 

replacement parts are needed.

Maintenance of Glass Doors

Cleaning

Smoke residue may build up on glass doors over time. 

Doors may be cleaned as necessary using nonabrasive 

glass cleaners. Use of abrasive cleaners may damage the 

surface of the glass and cause breakage. never attempt 

to clean glass panels while hot.

Replacement of broken glass

never operate a fireplace with cracked or broken glass 

panels. Replace any damaged parts before use.

NOTE:  Since  the  ceramic  glass  on  these  models  is 

quite fragile and proper mounting is critical for safety, 

damaged glass on the BFC models should be replaced 

by installing a new glass in the door assembly. Do not 

attempt to install new glass in the door frames. Re-

9.  The first few fires should be small.
10. Do not overfire your fireplace.
11. Always keep the fireplace screens completely closed 

while the fire is burning.

12. never place any combustible objects (furniture, pillows, 

etc.), closer than 2 inches (610 mm) from fireplace 

(28 inches (711 mm) for WMC/CWC and 32 inches 

(813 mm) for EWF36A).

13.  never  allow  anything  to  obstruct  the  air  inlet/outlet 

grilles.

Glass Door Precautions

1.  Always start the fire with the doors open.
2.  When  the  doors  are  open,  the  screens  must  be 

closed.

3.  If unit has an adjustable flue damper, open flue damper 

fully before opening the doors to prevent smoke from 

escaping into the dwelling.

.  Do not build extremely large fires as they could damage 

the finish and tempered glass.

5.  never allow the flames from the fire to contact the door 

glass.

6.  Always keep the bottom air inlet channel free of obstruc-

tions.

7.  To prevent discoloration on brass finished doors, check 

finish for a protective plastic coating and remove if ap-

plicable.

8.  Do not use abrasive cleaners on glass doors.
9.  Do not clean while hot.

Maintenance and Care of Your Fireplace

Your fireplace is built to operate trouble-free with little need 

for extensive time-consuming maintenance. As with any 

such piece of equipment, your fireplace will operate better 

and provide longer service if a few basic housekeeping 

procedures are followed.

In the Fall - 

Before the First Seasonal Use of the Fireplace

1.  Inspect the roof in the area of the chimney and remove 

any obstructions or foreign material such as hanging 

tree limbs, broken tree branches, leaves, etc.

2.  Inspect  the  chimney  top  housing,  removing  any  for-

eign obstructions from cooling air inlets and bird guard 

screen.

3.  Inspect the flue for obstructions and foreign material 

and remove them if any are found.

.  Creosote - Formation and need for Removal
When  wood  is  burned  slowly,  it  produces  tar  and  other 

organic  vapors,  which  combine  with  expelled  moisture 

to form creosote. The creosote vapors condense in the 

relatively cool chimney flue of the slow burning fire. As a 

result,  creosote  residue  accumulates  on  the  flue  lining. 

When ignited this creosote makes an extremely hot fire. 

Summary of Contents for BC36

Page 1: ...sir avec votre foyer bois BC BFC BR CWC EWF ODSR ODWR SC SR STR WBST WC WR and WMC Series Fireplaces Save This Homeowner s Manual Conservez ce manuel du propri taire 20000706 1 13 Rev 16 Foyers S ries...

Page 2: ...ions 8 Maintenance and Care of Fireplace 9 Troubleshooting Guide 10 Accessories 11 Table of Contents Table des Mati res Faites connaissance avec votre foyer 15 Mode d emploi de votre foyer 17 Mesures...

Page 3: ...u write the serialization number a series of letters and num bers located below the model number on the warranty card The serial number is stamped into the black plate attached to the inner dome side...

Page 4: ...the primary air control regulates the amount of heat the fire will produce and how long it will burn The primary air control is located in the upper left corner of the unit It is the primary source of...

Page 5: ...of the firebox The damper is opened by rotating the lever to the right The damper is closed by pushing the lever to the left and is locked closed by the damper clip located on the dome The damper is...

Page 6: ...e air operation Fig 4 Log placement on grate MD706 5 Basic Log Set up 1 19 99 MD706 5 replacing the basket grate a specific model must be used Refer to Page 12 for the model number The EWF does not us...

Page 7: ...eries fireplaces are designed for maximum heat output with doors fully closed at all times NOTE The BFC fireplace should be operated only with the doors fully closed NOTE The EWF fireplace should be o...

Page 8: ...ogs on end in the corners of the firebox In this position they usually will quickly burn out and will provide good base for your next fire Be sure the firescreen or glass doors are kept closed and the...

Page 9: ...small 10 Do not overfire your fireplace 11 Always keep the fireplace screens completely closed while the fire is burning 12 Never place any combustible objects furniture pillows etc closer than 24 in...

Page 10: ...discontinues You may have an obstruction in your flue or debris in or on chimney top Check for obstruction and remove If you fail to inspect your chimney flue as recommended creosote buildup may have...

Page 11: ...d air items one at a time Watch candle flame If flame is drawn away from the fireplace open an outside door or window If flame returns to upright position these systems are us ing the fireplace system...

Page 12: ...K8 or S 8 3041130 WR500 42GDKBKSR 203 mm 42GDKDPSR 42GDKSSR ODSR42A AKU1 N A 42GDKBBSR SK8 or S 8 20002230 ODWR500 42GDKBKSR 203 mm 42GDKDBSR 42GDKSSR 42GDKSSSR STR36 AK MST N A 36GDKBB SK8 only 8 205...

Page 13: ...20000706 13 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Page 14: ...14 20000706 Beaucoup de plaisir avec votre foyer bois Foyers S ries BC BR BFC CWC EWF ODSR ODWR SC SR STR WBST WC WR et WMC...

Page 15: ...z la carte de garantie et postez la Vermont Castings Group Pour valider votre garantie vous devez inscrire sur la carte de garantie le num ro de s rialisation s rie de lettres et de chiffres situ e so...

Page 16: ...se d un conduit allant du foyer une source d air ext rieur lors de l installation initiale Les foyers des s ries BC BR ODSR ODWR SC SR STR WBST WC et WR comportent ce dispositif standard Une source d...

Page 17: ...itr es sont ferm es et que la fum e n apparaisse pas dans l aire de combustion Le rendement le plus efficace est obtenu dans la position la moins ouverte Pour r approvisionner en bois ouvrez compl tem...

Page 18: ...us pouvez sentir une l g re odeur et voir de la fum e provenant de celui ci ou des grilles de refoulement de circulation de chaleur Cela est d la cuisson de la peinture et la combustion 2 Allumage du...

Page 19: ...le sens des aiguilles d une montre et ferm e quand il est tourn dans l autre sens Pour r gler la combustion ajustez la commande dans la position d sir e entre ces deux points quand la commande d air...

Page 20: ...limination des cendres Nettoyer les cendres de la chambre de combustion avant d allumer chaque feu Disposez ad quatement des cen dres dans un r cipient m tallique comportant un couvercle herm tique Me...

Page 21: ...r le registre Mesures de pr caution Bien que les mesures de pr caution suivantes aient t pr sent es plus haut dans ce manuel elles sont indiqu es ici pour insister et fournir une r f rence rapide Mesu...

Page 22: ...tre inspect e au moins une fois tous les deux 2 mois pendant la saison de chauffage Si une couche important de cr osote s est accumul e celle ci doit tre enlev e pour r duire le risque de feu de chem...

Page 23: ...e pour soulever le feu au dessus de l tre Cela est important pour obtenir un bon tirage Laissez le feu s teindre et reconstruisez le conform ment aux directives pr c dentes La t te de votre chemin e p...

Page 24: ...e porte ext rieure ou une fen tre Si la flamme revient en position verticale ces dispositifs utilisent le foyer pour obtenir l air d appoint ce qui provoque les diverses situations d apparition d air...

Page 25: ...42GDKDP 42GDKS BR42 AK MST S O 42GDKBB SK8 or S 203 mm 3030129 42GDKBK 8 po 42GDKDP 42GDKS SC36A AK MST FK12 36GDKBBSR SK8 or S 203 mm 3041130 WC400 36GDKBKSR 8 po 36GDKDPSR 36GDKSSR SR36A AK MST S O...

Page 26: ...Du conduit Grille STR36 AK MST S O 36GDKBB SK8 203 mm 2056100 424WBST 36GDKBK seulement 8 po 36GDKDP 36GDKS WMC36 STD STD STD S SK8 203 mm RSBG36 CWC400 8 po WMC42 STD STD STD S 203 mm RSBG36 CWC500 8...

Page 27: ...20000706 27...

Page 28: ...28 20000706 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Reviews: